feat(monitoring): alert when egress steering goes stale, not just when tun0 dies
`VPNTunnelDown` goes green the instant a tun0 exists, which is not the same as vpn-class pods having egress: Cilium caches (egress IP, egress ifindex) at first resolution, so after a reconnect the BPF egress map points at a destroyed interface and the packets are dropped while tun0 looks perfectly healthy. Dev sat in exactly that state for ~80 minutes with nothing alerting. Two rules close it: * VPNEgressSteeringStale (critical, for: 15m) — fires when the live tun0 was re-created more times in the last hour than the gateway node's `egress-uplink` label changed, i.e. Cilium was never told about a reconnect. * VPNEgressUplinkLabelMissing (warning, for: 30m) — the watchdog for the watchdog: a gateway node whose uplink label never reaches kube-state-metrics is a cluster where the rule above is inert. Both gated on a gateway node existing, reusing `VPNTunnelDown`'s `kube_node_labels` guard — a cluster with no gateway cannot be made to fire them. The direct label-vs-map comparison is NOT available and nothing was invented to pretend otherwise: no `cilium_*`/`hubble_*` series exist on either cluster (the cilium-agent exposes no metrics port, there is no ServiceMonitor), and Cilium OSS publishes no series carrying egress-map contents at all — the map is readable only via `cilium-dbg bpf egress list`. PromQL also cannot compare a metric value (the live ifindex) against a number inside a label value, so the level-triggered equality test is not expressible; the same invariant is counted over a window instead. Both limits, and the textfile-collector/black-box-probe routes that would lift them, are written down in the rule comments and the DECISIONS-LOG. `egress-uplink` added to kube-state-metrics.metricLabelsAllowlist in the same kustomization, because without it the first rule has nothing to compare. Verified read-only against LIVE prod (port-forward + /api/v1/query), rendered expr extracted from `kubectl kustomize platform-config`: empty when healthy; empty when evaluated at a timestamp before prod had a gateway node; and FIRING when pointed at a label that genuinely failed to follow prod's real 128 -> 129 tun0 flap earlier today. Nothing on prod was disturbed to produce that. Co-Authored-By: Claude Opus 5 <[email protected]>
This commit is contained in:
1 parent
19fc8bcb27
commit
16c6234696
4 files changed
+306
-1
No files matched your search
@@ -328,6 +328,132 @@ spec:
|
||||
summary: "Egress VPN tunnel down"
|
||||
description: "The egress-gateway VPN tunnel is down (or its metric is absent) for 5m — outbound traffic could leak or stall (leak risk, docs/07)."
|
||||
runbook_url: "https://${BASE_DOMAIN}/runbooks/vpn-down"
|
||||
# -----------------------------------------------------------------------------------------
|
||||
# THE BLIND SPOT `VPNTunnelDown` LEAVES (added 2026-09-12) — R-OBS-04, R-NET-06
|
||||
#
|
||||
# `VPNTunnelDown` goes green the instant a tun0 exists. That is not the same as vpn-class pods
|
||||
# having egress, because Cilium resolves a CiliumEgressGatewayPolicy's `interface: tun0`
|
||||
# exactly ONCE and caches an (egress IP, egress ifindex) pair. Every OpenVPN reconnect
|
||||
# re-creates tun0 with a NEW ifindex, so after the first reconnect the BPF egress map points
|
||||
# at a DESTROYED interface: `bpf_redirect()` fails and the packets are dropped — 0 out tun0,
|
||||
# 0 out the WAN (measured; there is no leak, there is simply no egress). tun0 is present and
|
||||
# carrying bytes the whole time, so `VPNTunnelDown` stays green. The dev gateway sat in
|
||||
# exactly that state for ~80 minutes on 2026-09-12 with nothing alerting.
|
||||
#
|
||||
# The datapath now self-heals: `roles/vpn_egress_gateway` publishes
|
||||
# `homelab.keithjackson.dev/egress-uplink=<tun0 addr>-<ifindex>` on the gateway node from the
|
||||
# OpenVPN up-script on every connect (plus a 2-minute convergence timer for the boot case),
|
||||
# and that node write is what makes Cilium re-resolve. These two rules watch whether it
|
||||
# ACTUALLY converged — if the re-steer mechanism itself fails we are back to a silent outage.
|
||||
#
|
||||
# WHY THIS SIGNAL AND NOT THE MAP ITSELF. The direct invariant is "the gateway node's
|
||||
# `egress-uplink` label == the Egress Ifindex in Cilium's BPF egress map". The map side is NOT
|
||||
# observable in Prometheus, verified on prod 2026-09-12 rather than assumed:
|
||||
# * the cilium-agent DaemonSet exposes no metrics port at all (`health=9879`,
|
||||
# `peer-service=4244`; only the OPERATOR has `operator-prometheus-serve-addr :9963`), and
|
||||
# there is no ServiceMonitor for cilium or hubble on either cluster — Hubble/Cilium
|
||||
# metrics export is still the open TODO in platform/cilium/helmrelease.yaml. Every
|
||||
# `cilium_*` and `hubble_*` query returns an empty vector today (which also means
|
||||
# `HubbleDeniedFlowSpike` above cannot fire yet).
|
||||
# * and even with agent metrics enabled, Cilium OSS publishes NO series carrying egress-map
|
||||
# CONTENTS. The map is readable only via `cilium-dbg bpf egress list` — a CLI over the BPF
|
||||
# map, not an exporter. No metric name is invented here to paper over that.
|
||||
# So the observable is the label: the input to the re-steer, compared against the live tun0
|
||||
# identity that node-exporter does export (`node_network_iface_id{device="tun0"}` — the real
|
||||
# ifindex, 129 on k3s-prod-3 right now, matching both the label `10.150.192.86-129` and
|
||||
# `cilium-dbg bpf egress list`'s `Egress Ifindex 129`, checked by hand on the live cluster).
|
||||
#
|
||||
# WHAT THIS DOES AND DOES NOT CATCH. It catches the whole input half: the up-script not
|
||||
# firing, the label write failing or never being deployed, the convergence timer being dead —
|
||||
# i.e. every way the tun0 identity can move without Cilium being told. It does NOT catch
|
||||
# "the label was written and Cilium still did not re-resolve"; nothing in Prometheus can,
|
||||
# until either the re-steer script exports the map's ifindex through a node-exporter textfile
|
||||
# collector (DECISIONS-LOG 2026-09-12, hand-off item 4) or a vpn-class black-box probe exists.
|
||||
# A probe was considered and rejected for now: there is no blackbox-exporter and no probe
|
||||
# CronJob in this repo, so it means a NEW always-on component whose own failures become a new
|
||||
# alerting surface — worth doing, but not as the thing that closes a hole today.
|
||||
#
|
||||
# WHY A `changes()` COMPARISON RATHER THAN AN EQUALITY TEST. PromQL cannot compare a metric
|
||||
# VALUE (the live ifindex) against a number embedded in a LABEL VALUE (`...-129`): there is no
|
||||
# label-to-number conversion, so the level-triggered equality test is not expressible. What IS
|
||||
# expressible is the same invariant counted over a window: the published label must change at
|
||||
# least as often as tun0 is re-created. `count(count_over_time(max by (<label>) (...)[1h:1m]))`
|
||||
# is the number of DISTINCT label values seen in the last hour (verified live: 1 for a label
|
||||
# that held still, 2 for one that changed value inside the window); the `max by (<label>)`
|
||||
# wrapper is load-bearing — it aggregates away `pod`/`instance`, so a kube-state-metrics
|
||||
# restart is not mistaken for a label change. Both sides reduce to a single unlabelled series,
|
||||
# which is why `and on()` joins cleanly, exactly as `VPNTunnelDown` does.
|
||||
#
|
||||
# Consequence, stated plainly: this is bounded by its window. A missed flap is alerted from
|
||||
# +15m to +1h and then the alert RESOLVES even if egress is still dead. That is a deliberate
|
||||
# trade against the repo's alert-fatigue history (an unbounded critical on the one channel
|
||||
# that must stay trustworthy is worse), and it still turns an 80-minute silent outage into an
|
||||
# email within 15 minutes. The textfile-collector gauge is what would make it level-triggered.
|
||||
- alert: VPNEgressSteeringStale
|
||||
# FIRES when the live tun0 was re-created more times in the last hour than the gateway
|
||||
# node's `egress-uplink` label changed — i.e. Cilium was not told about at least one
|
||||
# tunnel reconnect, so the BPF egress map is pointing at an ifindex that no longer exists
|
||||
# and vpn-class pods have no egress. Convergence is NOT this: the label is rewritten within
|
||||
# seconds of a connect (worst case ~5m, the up-script's 30 x 10s kube-API retry budget on a
|
||||
# cold boot), so `for: 15m` cannot fire on a healthy reconnect.
|
||||
expr: |
|
||||
(
|
||||
changes(max(node_network_iface_id{device="tun0"})[1h:1m])
|
||||
>
|
||||
(
|
||||
count(
|
||||
count_over_time(
|
||||
max by (label_homelab_keithjackson_dev_egress_uplink) (
|
||||
kube_node_labels{label_homelab_keithjackson_dev_egress_uplink!=""}
|
||||
)[1h:1m]
|
||||
)
|
||||
) - 1
|
||||
)
|
||||
)
|
||||
and on()
|
||||
(count(kube_node_labels{label_homelab_keithjackson_dev_egress_gateway="true"}) > 0)
|
||||
for: 15m
|
||||
labels:
|
||||
severity: critical
|
||||
annotations:
|
||||
summary: "VPN egress steering is stale — vpn-class pods have no egress"
|
||||
description: >-
|
||||
The gateway node's tun0 was re-created without the `egress-uplink` label following it, so
|
||||
Cilium's cached egress ifindex points at a destroyed interface: egress-class=vpn pods are
|
||||
being dropped, silently, while tun0 still looks healthy. Compare
|
||||
`kubectl get nodes -L homelab.keithjackson.dev/egress-uplink` against
|
||||
`cilium-dbg bpf egress list` on the gateway node; re-applying the CiliumEgressGatewayPolicy
|
||||
(or setting any node label) forces a fresh resolution.
|
||||
runbook_url: "https://${BASE_DOMAIN}/runbooks/vpn-egress-stale"
|
||||
- alert: VPNEgressUplinkLabelMissing
|
||||
# The watchdog for the rule above: `VPNEgressSteeringStale` needs the `egress-uplink` label
|
||||
# in kube-state-metrics, and if that label is missing its comparison degrades to an empty
|
||||
# vector — it fails OPEN, alerting nothing. So alert on the precondition itself. A gateway
|
||||
# node with no published uplink means the re-steer mechanism is not in place at all
|
||||
# (roles/vpn_egress_gateway not applied on this node, the up-script never ran, or the
|
||||
# kube-state-metrics label allowlist in kube-prometheus-stack.yaml lost the entry), which is
|
||||
# the configuration that produced the 80-minute dev outage. Warning, not critical: it is a
|
||||
# rollout/config gap to fix in working hours, not a page. `for: 30m` so that the Helm upgrade
|
||||
# that rolls kube-state-metrics — both changes ship in this same kustomization — cannot page
|
||||
# on the way in, and so an Ansible run in progress does not either.
|
||||
expr: |
|
||||
(count(kube_node_labels{label_homelab_keithjackson_dev_egress_gateway="true"}) > 0)
|
||||
and on()
|
||||
absent(kube_node_labels{label_homelab_keithjackson_dev_egress_uplink!=""})
|
||||
for: 30m
|
||||
labels:
|
||||
severity: warning
|
||||
annotations:
|
||||
summary: "Egress gateway node publishes no egress-uplink label"
|
||||
description: >-
|
||||
A node carries `homelab.keithjackson.dev/egress-gateway=true` but no
|
||||
`homelab.keithjackson.dev/egress-uplink` label is visible in kube-state-metrics. Without it
|
||||
nothing can tell whether Cilium's egress steering followed the last tunnel reconnect, and
|
||||
`VPNEgressSteeringStale` is inert. Check the label on the node, then the
|
||||
`vpn-egress-resteer` service/timer on the gateway node, then the kube-state-metrics
|
||||
metricLabelsAllowlist.
|
||||
runbook_url: "https://${BASE_DOMAIN}/runbooks/vpn-egress-stale"
|
||||
# -----------------------------------------------------------------------------------------
|
||||
# (ADR-0015) The former `EgressGatewayUnhealthy` pod-readiness alert was REMOVED with the gluetun
|
||||
# retirement: there is no in-cluster egress-gateway pod anymore (the tunnel is a host systemd
|
||||
# service, steering is Cilium eBPF). Tunnel + gateway-node health is covered by `VPNTunnelDown`
|
||||
|
||||
@@ -230,8 +230,20 @@ spec:
|
||||
# without anyone having to remember to re-enable it later. Scoped to one label on one resource:
|
||||
# 3 extra series, no cardinality concern. Label name is sanitized by KSM to
|
||||
# `label_homelab_keithjackson_dev_egress_gateway` (`label_` + non-alphanumerics -> `_`).
|
||||
#
|
||||
# ADDED 2026-09-12 — `homelab.keithjackson.dev/egress-uplink`. The gateway node publishes
|
||||
# `<tun0 address>-<ifindex>` here from the OpenVPN up-script on every connect (roles/
|
||||
# vpn_egress_gateway), and that node write is what makes Cilium re-resolve its cached egress
|
||||
# interface. Exporting the label is what lets `VPNEgressSteeringStale` and
|
||||
# `VPNEgressUplinkLabelMissing` (alerts.yaml) watch whether the re-steer mechanism actually
|
||||
# converged — the one thing nothing watched while the dev gateway sat dead for ~80 minutes.
|
||||
# Cost: the label exists on exactly ONE node (the singleton gateway), so this adds a label
|
||||
# DIMENSION to the same 3 `kube_node_labels` series, not new series. Its value changes only on
|
||||
# a tunnel reconnect (a handful of times a day at most), so the churn is negligible — but note
|
||||
# that a value change does retire one series and start another, which is precisely the property
|
||||
# the alerts key on. Sanitized name: `label_homelab_keithjackson_dev_egress_uplink`.
|
||||
metricLabelsAllowlist:
|
||||
- "nodes=[homelab.keithjackson.dev/egress-gateway]"
|
||||
- "nodes=[homelab.keithjackson.dev/egress-gateway,homelab.keithjackson.dev/egress-uplink]"
|
||||
resources:
|
||||
requests:
|
||||
cpu: 20m
|
||||
|
||||
Reference in new issue
Block a user