`instances: 3` + `podAntiAffinityType: required` fixed the INSTANCE spread but moved
the PRIMARY concentration from k3s-prod-2 to k3s-prod-1: all three primaries
(keycloak-db-2, nextcloud-db-2, semaphore-db-2) ended up on one node, so losing it
meant three simultaneous failovers.
There is NO declarative fix, established from the CRD installed on prod (CNPG 1.30.0,
clusters.postgresql.cnpg.io/v1) rather than from memory. Every spec.affinity field and
spec.topologySpreadConstraints applies to "all the cluster's pods" and is not role-aware;
spec.replica.primary names a Cluster object in a distributed topology, not a node;
primaryUpdateMethod/switchoverDelay/primaryLease govern how a promotion happens, never
where. `targetPrimary` exists only under STATUS, never spec — so `cnpg promote` is an
imperative status patch by construction and there is nothing to put in git. The obvious
workaround is worse than nothing: pod anti-affinity is only ever
...IgnoredDuringExecution while CNPG promotes by relabelling a RUNNING pod, and with
3 instances on 3 nodes it would leave the third instance unschedulable.
So this commits the part that IS durable — visibility — and rebalances live.
CNPGPrimariesCoLocated joins CNPG's own answer to "who is primary" (the <cluster>-rw
Service selects only the primary) against the node: kube_endpointslice_endpoints carries
endpoint_nodename + targetref_name, which two label_replaces lift into node/pod. Neither
family works alone — cnpg_* metrics have no node label, and kube_pod_labels is EMPTY here
(no kube-state-metrics label allowlist), so cnpg.io/instanceRole is not in Prometheus at
all. `* on (namespace, pod) group_left () cnpg_collector_up` keeps an unrelated `*-rw`
Service from triggering it, and uses the one metric present for EVERY instance rather than
the cnpg_pg_stat_* family that is missing for nextcloud-db.
A Ready-node gate stops this becoming another permanently-firing alert: with three
clusters on three nodes a node loss NECESSARILY co-locates two primaries, so the rule
only speaks when the spread is actually achievable, and re-arms when the node returns.
Proven both ways. Live: the expr returned {node="k3s-prod-1"} => 3 before, empty after,
with the inner join still resolving all three primaries (quiet because false, not blind);
loaded into prod's Prometheus as a throwaway `for: 1m` twin it went pending at +70s and
firing at +130s. alerts.promtool-test.yaml pins four cases under promtool 3.14.0 (the
exact version prod runs) and is mutation-checked — dropping the join, dropping the gate
or shortening `for:` each makes a test FAIL.
Rebalanced live, one cluster at a time: keycloak-db -> k3s-prod-2, nextcloud-db ->
k3s-prod-3, semaphore-db deliberately LEFT on k3s-prod-1 (lightest writer, and that node
has the known etcd/Longhorn I/O contention) — two switchovers, not three. Write outage
measured with a `select txid_current()` probe, not estimated: 9.4s and 9.43s, one
contiguous burst each. All three back to readyInstances: 3 with
synchronous_standby_names = ANY 1 (...) and both standbys streaming/quorum.
The placement is CURRENT, NOT DURABLE, and the alert is the point: the next failover or
rolling update can re-concentrate the primaries, and now that gets reported instead of
discovered by hand.
Co-Authored-By: Claude Opus 5 <[email protected]>