The first real SMART run FAILED k3s-prod-1's drive on reallocated=61440. That verdict
was WRONG, and the failure mode is instructive: the check trusted a VENDOR-DEFINED raw
value as if it were an ATA-standard sector count.
Micron TN-FD-20 ("SMART Attributes for the C400 SSD") names attribute 5 "Reallocated
BLOCK Count" and defines its raw as grown-bad-blocks x Block_Sector_Count, where
Block_Sector_Count is 256 x 16 = 4096 for the 128Gb-NAND parts (256GB/512GB). This is
the 512GB C400-MTFDDAC512MAM: 61440 / 4096 = 15. Triply corroborated on the drive itself
— attr 170 Grown_Failing_Block_Ct = 15, attr 196 Reallocated_Event_Count = 15, attr 5
normalised value 100 against thresh 10, and `when_failed` empty on every attribute.
FIFTEEN grown bad blocks, not sixty-one thousand bad sectors.
smartctl(8) states it outright: since ATA/ATAPI-4 rev 4 the meaning of raw Attribute
fields is "entirely vendor-specific". So a raw value can never be a portable verdict.
FAIL now comes only from signals that mean the same thing on every drive: the drive's own
smart_status.passed; NORMALISED value vs the MANUFACTURER's own threshold via smartctl's
when_failed ("now"/"past"/""), split Pre-fail -> FAIL and Old_age-or-past -> WARN; the
ATA-standard counters 197/198/187 (199 CRC is WARN-only — it is link, not media); and for
NVMe critical_warning / media_errors / percentage_used. Wear reads from the NORMALISED
lifetime indicator (202/231/233, or NVMe percentage_used) — a percentage by definition.
Vendor raw counts are still collected and PRINTED WITH THEIR NUMBERS, and may raise a
WARN, but can never drive a FAIL. Attribute 5's raw is now shown beside the normalised
reading that contradicts it, labelled vendor-encoded, with a mechanically-derived
"(= 15 x 4096)". Endurance attributes are matched by THE NAME smartctl's drivedb resolved
for that model, not by bare ID — drivedb is the portability layer; on an unrecognised
drive the name is Unknown_Attribute, nothing matches, and the field stays null with no
claim made. The STORAGE section now prints 170/172/173/174/189/206, whose previous
omission is exactly what let the misread stand unchallenged.
Also documented from TN-FD-20: on this family attr 197 "will always be 0, as reallocation
will be done on-the-fly" — so pending=0 is NOT evidence of health here. The role reports
the number and infers nothing from it.
Branches real hardware cannot exercise were verified with a harness rendering the actual
role expressions against synthetic smartctl payloads: virtio/no-stdout -> SKIP; NVMe
healthy -> PASS; NVMe degraded -> FAIL; a genuinely dying ATA drive (attr 5 normalised 8
<= thresh 10, pending 48) -> FAIL driven by the threshold trip and standard counters, not
the raw; unknown-vendor attrs -> PASS with the unnamed counter ignored; failed-in-the-past
-> WARN.
NEW VERDICTS. k3s-prod-1: 0 FAIL / 4 WARN / 12 PASS / 1 SKIP — SMART is a WARN naming the
real findings (31% of rated life consumed, 15 grown bad blocks, 187 erase failures, 32
unexpected power losses on a drive with no power-loss protection). k3s-dev-1: unchanged,
all three virtio disks still SKIP with their stated reason.
BREAKING (JSON artifact): the fact `reallocated_sectors` is renamed and gone — that name
asserted a unit ATA does not guarantee. Replaced by realloc_attr (the whole attribute,
normalised + raw), realloc_events, and grown_bad_blocks. Nothing in the repo reads it.
Serves: R-ENV-03, R-OBS-04.
Co-Authored-By: Claude Opus 5 (1M context) <[email protected]>
node_health — read-only node hardware health
Sibling of roles/cluster_verify. cluster_verify answers "is the cluster healthy";
node_health answers "is the hardware under it healthy". Same posture: it inspects and
reports, it never changes the node.
Serves R-ENV-01 (you cannot certify a node you have not measured), R-ENV-03 (bare-metal parity with dev) and R-OBS-04 (node-level observability).
# prod (all nodes in the k3s_prod group)
./infra/devcontainer/dev.sh run bash -c \
'cd /work/infra/ansible && ansible-playbook playbooks/node-health.yml -e node_health_hosts=k3s_prod'
# dev (default target), one node
./infra/devcontainer/dev.sh run bash -c \
'cd /work/infra/ansible && ansible-playbook playbooks/node-health.yml --limit k3s-dev-1'
Contract
- Read-only and side-effect-free. It reads
/sys,/proc,/etc, runslsblk/lscpu, and — only when it can escalate —smartctl. It writes nothing to the node and installs nothing.smartmontoolsis declared innode_baseline_packages; if it is absent the SMART checks SKIP with that as the stated reason (operator ruling 2026-08-31: package installation isnode_baseline's job, never a health check's, never a manualapt-get). - A skip is honest; a fake green is a defect. Every check is
PASS/WARN/FAIL/SKIP/INFO, and aSKIPalways carries why it could not be measured. Nothing that was not read is reported as passing. The summary ends with a dedicated "NOT READ (and why) — these are UNKNOWNS, not passes" section. - Works on bare metal and VMs. Everything absent in a guest (SMART on virtio, DMI,
EDAC,
coretemp, CPU throttle counters) skips cleanly instead of erroring. Verified against bothk3s-prod-1(HP EliteDesk, bare metal) andk3s-dev-1(Proxmox VM). - Never
becomes unless it must. Only SMART needs root.
What it checks
| id | what |
|---|---|
access.privilege |
whether become works at all (gates the root-only checks) |
storage.smart.<disk> |
overall-health, normalised-vs-threshold trips, pending/uncorrectable/CRC counters, lifetime remaining, wear + endurance context, drive temperature — root only. See How the SMART verdict is reached |
storage.io_errors |
kernel SCSI/ATA ioerr_cnt / iotmo_cnt per disk (no root needed) |
storage.capacity, storage.inodes |
worst mounted filesystem, space and inodes |
storage.layout |
physical disks, and whether any device is genuinely free for node_baseline_longhorn_device / node_baseline_etcd_device |
memory.available, memory.swap, memory.ecc |
headroom, kubelet's swap-off prerequisite, EDAC correctable/uncorrectable counters |
cpu.throttle, cpu.inventory, cpu.virtualisation |
thermal throttle events since boot, topology + frequency scaling, VT-x/AMD-V + /dev/kvm (KubeVirt, R-PLAT-03) |
thermal.max |
hottest sensor across thermal zones and hwmon chips |
pressure.cpu / .memory / .io |
PSI some avg60 — dev learned to care about CPU PSI specifically |
network.link, network.errors, network.resolvers |
link state/speed, NIC error counters, DNS upstream redundancy per address family |
os.reboot_required, os.inventory, firmware.inventory |
pending reboot, OS/kernel/uptime, chassis + BIOS |
Thresholds live in defaults/main.yml (node_health_thresholds); no verdict is hardcoded
in task logic.
Output
- A human summary printed in the play output.
- The same summary and a structured JSON record under
infra/ansible/_artifacts/node-health/<host>.{txt,json}.
_artifacts/ is in infra/ansible/.gitignore — the same convention as
conformance/_artifacts/. Generated output is never committed (it also carries drive
serial numbers).
The become subtlety (read before editing)
ansible_become set as an inventory/group var — which is exactly what
inventory/group_vars/k3s_prod/vars.yml does — is a connection variable, and
connection variables outrank the become: play/task keyword. Verified on
ansible-core 2.20: a task saying become: false still tries to sudo and, on prod, dies
with Missing sudo password before the module runs. So this role overrides the
variable (vars: ansible_become: false) on the unprivileged work, and probes
escalation exactly once before attempting SMART.
Equally verified: failed_when: false does not catch a missing-sudo-password error
(it is raised by the become plugin before the failure expression is evaluated);
ignore_errors: true does, and still populates the registered variable. That is why the
escalation probe uses ignore_errors — anything else turns "no vault yet" into a hard,
misleading play failure.
How the SMART verdict is reached
SMART raw values are vendor-defined and this role does not judge on them. smartctl(8) is explicit: "starting with ATA/ATAPI-4, revision 4, the meaning of these Attribute fields has been made entirely vendor-specific."
This is not theoretical. The first real run of this role FAILED k3s-prod-1's
Crucial/Micron C400 (C400-MTFDDAC512MAM, fw 070H) on reallocated=61440, read as a
plain bad-sector count. Micron's own TN-FD-20 SMART Attributes for the C400 SSD defines
attribute 5 not as a sector count but as Reallocated Block Count, whose raw is "the
grown NAND Flash bad-block count multiplied by the Block_Sector_Count, which is 256 x 8 for
64Gb NAND ... or 256 x 16 for 128Gb NAND (256GB and 512GB)". For this 512GB drive that
multiplier is 256 x 16 = 4096, and 61440 / 4096 = 15 — corroborated on the same drive by
attribute 170 Grown_Failing_Block_Ct = 15 and attribute 196 Reallocated_Event_Count = 15.
Fifteen grown bad blocks, not sixty-one thousand bad sectors. The verdict was wrong by a
factor of 4096 because it assumed a unit the ATA spec does not guarantee.
What the check judges on instead
Vendor-independent signals only, each of which means the same thing on every drive:
- The drive's own overall-health self-assessment (
smart_status.passed) — FAIL. - Normalised VALUE vs the MANUFACTURER'S OWN THRESHOLD, taken from smartctl's
when_failedfield ("now"/"past"/""). Per smartctl(8),FAILING_NOWmeans the normalised value is at or below the threshold the manufacturer set for that attribute on that model; a dash means it is OK now and has never failed. This needs no per-vendor knowledge from us — the vendor already encoded the answer. Pre-fail failing now → FAIL; Old_age failing now, or anything that failed in the past → WARN. - ATA-standard error counters whose raw meaning is a plain event count everywhere: 197 pending, 198 offline-uncorrectable, 187 reported-uncorrectable → WARN/FAIL; 199 CRC (SATA link, not media) → WARN only.
- NVMe's structured health log —
critical_warning,media_errors,percentage_used. - Wear from the NORMALISED lifetime indicator (ATA 202/231/233
value, or NVMepercentage_used) — a percentage by definition, and therefore portable where raw wear counts are not.
What is reported but never produces a FAIL
Vendor raw counts are real information and are all printed with their numbers — grown bad-block count, reallocation events (196), erase/program failures, unexpected power losses, and attribute 5's raw shown beside the normalised reading that contradicts it. They can raise a WARN, never a FAIL, because their units are vendor-defined.
The endurance counters live in the vendor-specific attribute-ID range (170-174), so they are
matched by the name smartctl's drive database resolved for that model, not by a bare ID:
drivedb.h is smartmontools' own per-(model, firmware) translation, so keying off its
resolved name borrows that portability instead of hardcoding one vendor's layout. On a drive
drivedb does not recognise, the name is Unknown_Attribute, nothing matches, and the field
stays null — no claim is made either way.
Two honesty traps this check does not fall into
- Zero is not a clean bill of health. Micron TN-FD-20 states attribute 197 on the C400 "will always be 0, as reallocation will be done on-the-fly". A non-zero 197 is a finding; a zero one proves nothing. The role reports the number and does not infer health from it.
- A quiet drive is not necessarily a good drive.
overall-health=PASSEDwith every threshold un-tripped can still sit alongside a third of rated life consumed, grown bad blocks, erase failures and unprotected power losses — which is exactlyk3s-prod-1. Those produce a WARN with the numbers, because a check that called that drive "fine" would be worse than the false FAIL it replaced.
Known limits
- Without root: no SMART (wear, power-on hours, error counters, drive
temperature) and no DMI serial numbers. On prod that means creating
inventory/group_vars/k3s_prod/vault.yml(see that directory's README) and runningnode-baselinesosmartmontoolsexists — in that order. - EDAC reports nothing on platforms with no ECC memory controller bound. That is "ECC status unknown", not "no errors", and the role says so.
- SMART wear and endurance context depends on smartmontools'
drivedb.hknowing the drive. On an unrecognised model the vendor attributes areUnknown_Attribute; the portable signals (overall health, normalised-vs-threshold, 197/198/187/199, NVMe log) still apply, but the wear/endurance context SKIPs rather than guessing. ioerr_cntcounts commands the kernel saw fail, which includes benign rejected or unsupported commands during discovery. Attribution needsdmesg, which needs root.