jakman85 3c8f809aaf docs(prod): CORRECTION — BIOS attributes are read-only in practice, not writable
I recorded that the hp-bioscfg attributes were 'writable from the OS' because current_value
has mode rw and no BIOS passwords are set. That was WRONG, and the firmware said so when the
write was actually attempted:

  hp_bioscfg: Returned error 0x4, "Invalid command type"   (surfaces as printf: I/O error)

HP requires BIOS-admin authentication for programmatic changes and neither credential is
provisioned on these nodes — Setup Password is_enabled=0 (role bios-admin), SPM
key_mechanism=not provisioned. Secure Boot is also enabled. File mode is not authority; the
firmware is.

What survives the correction, and it is the useful half: READS WORK. Diffing 215 attributes
between node 1 and node 2 is exactly how the drift in §0b was found — nobody spots
'After Power Loss=Power Off' by eye. So the §1 firmware checklist IS machine-CHECKABLE today
with reads alone, and node_health should assert it.

What does NOT survive: machine-ENFORCEABLE. Converging BIOS settings automatically would
require provisioning a BIOS Setup Password on every node — a stored credential that can rewrite
firmware. That is a real security decision and the operator's call, not something to default to.

Consequence for the node-2 memory fault: setting Fast Boot=Disable and After Power Loss=Power On
must be done in F10 on the box. Updated §0b and §1 accordingly.

Serves: R-ENV-03. Task: T-7.1.
2026-09-01 21:45:15 -05:00

30 KiB
Raw Blame History

Prod bare-metal provisioning checklist (T-7.1)

Task: T-7.1 · Workstream: WS-INFRA · Serves: R-ENV-01, R-ENV-02, R-ENV-03, R-PLAT-01/03 Status: Phase 7 opened by the operator 2026-08-31 — prep only. Nothing is installed on prod hardware until the blockers in §7 are closed and make -C ci gate is green.

Entry-gate note (recorded, not waived). roadmap/phases.md gates Phase 7 on "Phases 1–6 proven in dev/test; operator declares prod hardware ready." The operator has declared hardware ready. The first condition is not met: conformance is 37/51, and the uncovered set includes R-ENV-01/02/03 — the very requirements this document serves. We proceed with prep work knowingly; see DECISIONS-LOG.md (2026-08-31 Phase-7 entry).

Prod is 3× mini-PC bare metal (spec docs/02). The dev path (OpenTofu → Proxmox VM → cloud-init) does not apply: there is no hypervisor API to call. Stage 1 "Create" is a human imaging a box. Stages 2–4 (baseline, cluster-join, manage) reuse the same Ansible roles and the same Flux base as dev — that reuse is the R-ENV-02 obligation.


0. Node inventory

Fill a row per node as it lands. Node 1 is as-found on 2026-08-31.

node 1 node 2 node 3
Hostname k3s-prod-1 k3s-prod-2 k3s-prod-3
LAN IP 192.168.2.10 192.168.2.11 192.168.2.12
Model HP EliteDesk 800 G5 Desktop Mini
CPU i7-9700T, 8c/8t, VT-x
RAM 31 GiB
Disks 1× 477 GB SATA SSD (C400-MTFDDAC512M)
OS Debian 13 (trixie), kernel 6.12
Firmware HP R21 Ver. 02.26.00
/dev/kvm present

Dev nodes for comparison: 8 vCPU / 24 GiB / Debian 13, two dedicated data disks (Longhorn + etcd).


0b. OPEN HARDWARE FAULT — k3s-prod-2 can only address ~2.6 GiB of its 16 GB

Found 2026-09-01 by playbooks/node-health.yml on node 2's first health run. Do not install more RAM until this is understood — see the warning at the end.

Evidence Reading
DMI (dmidecode -t memory) 16 GB Samsung M471A2K43DB1-CTD in DIMM1 @ 2667 MT/s, DIMM3 empty
BIOS e820 map reports ~16 GiB usable, incl. 0x100000000-0x42f7fffff
Kernel summary Memory: 2568544K/16546088K available (13958980K reserved)
last_pfn revised down from 0x42f800 (~16.7 GiB) to 0xc3c10 (~3.06 GiB) in early boot
Zones Normal zone present 3340288 pages (~12.7 GiB) but managed 0
MemTotal 2,753,284 kB ≈ 2.6 GiB
Memory blocks 127 online, 128 MiB block size

The DIMM is healthy. It is present, correctly identified, and running at its rated speed. The kernel sees all 16 GB and then reserves 13.3 GiB of it. Everything below ~3 GiB is usable and everything above 4 GiB is present-but-unmanaged — the classic signature of memory remapping above 4 GB not being applied, not of failing memory.

Node 1 is the control: identical HP EliteDesk 800 G5 Mini, identical BIOS R21 Ver. 02.26.00, identical i7-9700T — and it addresses its full 31 GiB. So this is not a firmware-version defect; it is per-machine state.

BIOS settings compared programmatically (2026-09-01). Both nodes load the hp-bioscfg kernel driver, which exposes 215 BIOS attributes read/write at /sys/class/firmware-attributes/hp-bioscfg/attributes/<name>/current_value. No BIOS passwords are set (authentication/*/is_enabled = 0).

They are READ-ONLY in practice, despite current_value having mode rw. A write attempt was made on 2026-09-01 and the FIRMWARE refused it: hp_bioscfg: Returned error 0x4, "Invalid command type", surfacing as printf: I/O error. HP requires BIOS-admin authentication for programmatic changes, and both credentials are absent — Setup Password is_enabled=0 (role bios-admin) and SPM key_mechanism=not provisioned. Secure Boot is also enabled. So BIOS changes on these nodes are an F10 exercise unless a BIOS Setup Password is deliberately provisioned (see §1).

What the comparison ruled OUT as the cause:

  • Firmware inventory is correct. Node 2's BIOS itself reports Memory Size=16384 MB and Processor 1 DIMM1=16 GB Samsung / DIMM3=Empty. The firmware is not under-counting.
  • No memory-remap / above-4G-decoding attribute exists on this platform — not present on either node, so it cannot be a mis-set option.
  • MTRRs are effectively identical between the nodes and there is no MTRR trim warning, which rules out the classic "BIOS bug: MTRRs don't cover all of memory, losing N MB" path.
  • /proc/iomem registers 100000000-42f7fffff as System RAM and 127 × 128 MiB memory blocks report online. The memory reaches the kernel and is then reserved.

Real BIOS differences found (node 1 = works, node 2 = broken):

Attribute node 1 node 2
After Power Loss Power On Power Off ← violates §1
Fast Boot Disable Enable ← leading hypothesis
Legacy Boot Options Disable Enable
TPM Activation Policy F1 to Boot Allow user to reject
Microsoft/Windows UEFI CA 2023 Enable Disable
Memory Size 32768 MB (2×16 GB Micron) 16384 MB (1×16 GB Samsung)

Leading hypothesis: Fast Boot=Enable. HP Fast Boot reuses cached memory-training data rather than retraining at each boot. If the DIMM was fitted while Fast Boot was on, stale training data is a plausible route to memory being present, inventoried, handed over — and then reserved. It is also the one memory-relevant setting that differs from the working node. This is a hypothesis, not a conclusion: it was NOT tested, because changing it requires a firmware write and a reboot, which needs operator sanction.

To investigate, cheapest first:

  • Set Fast Boot=Disable and reboot (tests the hypothesis directly, and matches node 1). Must be done in F10 — the firmware refuses programmatic writes (above).
  • Set After Power Loss=Power On regardless of the memory question — §1 requires it and node 2 currently violates it.
  • Clear CMOS / load setup defaults on node 2 to force a full memory retrain, then re-check.
  • Compare node 2's BIOS settings against node 1 directly. Look for a memory remap / "Above 4G decoding" style option, and for any memory-limit or 32-bit-addressing setting.
  • Clear CMOS / load setup defaults on node 2, then re-check MemTotal.
  • Reseat the DIMM; try it in DIMM3; try it in node 1 (swap test) — that isolates DIMM vs slot vs board in one move.
  • memtest86+ if the above do not resolve it.

⚠ Do not assume the incoming 32 GB fixes this. If the fault is the slot, the board, or a BIOS setting rather than the DIMM, 32 GB will present exactly the same way and the money is wasted. Verify MemTotal after any RAM change — playbooks/node-health.yml -e node_health_hosts=k3s_prod reports it. A node that can address 2.6 GiB cannot run k3s + Longhorn + a workload share.

1. Firmware / BIOS (per node, before OS install)

These are MACHINE-CHECKABLE — but NOT machine-enforceable. The hp-bioscfg driver exposes 215 BIOS attributes at /sys/class/firmware-attributes/hp-bioscfg/attributes/, and reads work fine: node 1 and node 2 were diffed programmatically, which is how the drift in §0b was found at all. Nobody could have spotted After Power Loss=Power Off on node 2 by eye.

Writes are refused by the firmware — verified 2026-09-01, hp_bioscfg: Returned error 0x4, "Invalid command type". HP requires BIOS-admin authentication and neither credential is provisioned (Setup Password is_enabled=0, SPM not provisioned). Setting these therefore means F10 on the box.

Follow-up worth doing: extend roles/node_health to ASSERT this checklist — that is achievable today with reads alone, and would have caught node 2's drift on its first health run. Converging it automatically additionally requires provisioning a BIOS Setup Password on every node, which is a real security decision (a stored credential that can rewrite firmware) and is the operator's call, not a default.

  • Virtualization enabled — VT-x and VT-d. Required for KubeVirt (R-PLAT-03); verify after boot with /dev/kvm present and grep -cE 'vmx|svm' /proc/cpuinfo non-zero.
  • AC power recovery = Power On. A homelab node must return after a power cut without a human pressing the button. (docs/02 calls out wake/boot behaviour explicitly.)
  • Wake-on-LAN enabled on the onboard NIC (remote recovery when the box is off).
  • Boot order — internal disk first; USB above it only while imaging. Disable network boot unless PXE is adopted.
  • Secure Boot — record the setting. k3s itself is fine either way; note it so all three nodes match.
  • Firmware version recorded in §0 and consistent across all three nodes.

2. Disk layout — OPEN DECISION, blocks the build

docs/02 requires the OS-vs-Longhorn device split to be documented before prod build. Dev went further and added a third device for etcd after HDD contention starved etcd WAL fsync (docs/plans/ssd-etcd-isolation.md).

Node 1 as-found is a single 477 GB SATA SSD carrying everything:

sda  477G  C400-MTFDDAC512M (SSD, ~2011-era Micron/Crucial)
├─sda1 976M  /boot/efi
├─sda2  30G  /
├─sda3  12G  /var
├─sda4 977M  swap
└─sda5 433G  /srv          <- the only large free space

Consequences to settle before imaging nodes 2 and 3:

  • Drive health MEASURED 2026-09-01 (smartctl -a /dev/sda, via the baseline package floor — see §5). Raw attributes, so the numbers are auditable:

    | | |
    |---|---|
    | Model | Crucial/Micron RealSSD m4/C400/P400 (`C400-MTFDDAC512MAM`, fw `070H`) |
    | SMART self-assessment | **PASSED** — no attribute in `WHEN_FAILED` |
    | Power-on hours | 6,814 (~284 days) · 147 power cycles |
    | **Rated life used** | **31%** (`202`), i.e. 69% remaining (`173` VALUE 069) |
    | **Grown failing blocks** | **15** (`170`), reallocation events **15** (`196`) |
    | **Erase failures** | **187** (`172`) |
    | **Unexpected power losses** | **32** (`174`) |
    | Pending / offline-uncorrectable / reported-uncorrectable | **0 / 0 / 0** (`197`/`198`/`187`) |
    | UDMA CRC errors | 0 (`199`) — cabling is clean |
    
    **Read attribute `5` carefully.** Its raw value is `61440`, which is NOT a bad-sector
    count: `61440 = 15 x 4096`, and both `170` and `196` independently read **15**. Its
    normalised VALUE is 100 against a THRESH of 10. So the drive has **15 grown bad blocks**,
    not sixty-one thousand bad sectors. The first `node_health` run FAILED on that raw value;
    the check now judges on normalised VALUE/THRESH, `WHEN_FAILED`, and the vendor-independent
    uncorrectable counters instead.
    
    **Verdict: usable, but not for production state.** Nothing says imminent failure — no
    pending or uncorrectable sectors, SMART self-assessment passes. But this is a ~2011
    consumer MLC drive that has already consumed **31% of its rated life**, grown **15** bad
    blocks, logged **187** erase failures, and taken **32** unclean power losses **with no
    power-loss protection**, in a single failure domain. etcd is the worst possible tenant for
    it: etcd fsyncs constantly, and an unclean power loss on a drive without PLP is exactly how
    a member corrupts — this drive has already logged 32 of them.
    (Non-ECC RAM is a separate, **accepted** risk — operator decision 2026-09-01, see
    `DECISIONS-LOG.md`. It is not part of this verdict.)
    
  • Decide the layout.- [ ] Decide the layout. roles/node_baseline expects block devices (node_baseline_longhorn_device, node_baseline_etcd_device) and makes a filesystem on them. Its defaults /dev/vdb and /dev/vdc are virtio names that do not exist on bare metal — prod must override them in group_vars. On a single-disk node there is no second device at all, so one of: - Add a second drive (M.2 NVMe if the chassis has a free slot; verify physically — only a SATA controller is populated today). Cleanest: matches dev's isolation, gives etcd its own spindle. - Use /dev/sda5 (the 433 GB /srv partition) as the Longhorn device, etcd stays on /. Buildable today, zero spend, but re-creates the shared-spindle contention dev was burned by. - Repartition into dedicated OS / etcd / Longhorn partitions. Better isolation, still one physical failure domain.

  • All three nodes get the identical layout. Longhorn replica placement assumes symmetry.

  • Record the chosen device paths here and set them in infra/ansible/inventory/group_vars/k3s_prod/vars.yml (they are deliberately /dev/BLOCKED-pending-disk-decision-… placeholders today — do not guess). A full node-baseline run against a node still carrying those placeholders now stops on an explicit assert naming this section, instead of failing obscurely at mkfs time.

  • The SMART-vs-smartmontools circular dependency is broken (2026-08-31). roles/node_baseline is tagged packages / system / disks, so the package floor can land without the disk tasks this decision blocks — see §5's drive-health box for the exact command.

3. OS install (per node)

  • Debian 13 (trixie), matching dev exactly — same kernel series, same package baseline.
  • Hostname k3s-prod-N.
  • Partition per the §2 decision.
  • No cloud-init needed. Dev's first-boot work was deliberately moved into roles/node_baseline when provisioning became API-only (infra/cloud-init/ is a README now), so the same role covers bare metal. Nothing to port.

4. Network (per node)

  • Static IP on the prod LAN, recorded in §0. Node 1 is 192.168.2.10/24, gateway 192.168.2.1.

  • Prod address plan — DECIDED (operator, 2026-08-31).

    | Role | Address | Owned by |
    |---|---|---|
    | `k3s-prod-1` / `-2` / `-3` | `192.168.2.10` / `.11` / `.12` | Ansible inventory |
    | **kube-vip control-plane VIP** | `192.168.2.9` | Ansible (`group_vars/k3s_prod`) |
    | **Ingress Gateway VIP** (`GATEWAY_VIP`) | `192.168.2.20` | Flux (`clusters/prod`) |
    | **Cilium L2 announcement pool** | `192.168.2.20` – `.30` | Flux (`platform-config/cilium`) |
    
    Two deliberate properties, both mirroring dev:
    - The **control-plane VIP sits outside the LB pool** (`.9`, below the nodes), so kube-vip and
      Cilium LB-IPAM can never contend for the same address. Dev achieves this the other way
      round (`.49` control-plane, pool `.53-.60`).
    - **`GATEWAY_VIP` is the FIRST address of the pool.** Cilium LB-IPAM can only allocate from a
      defined pool block, so a Gateway VIP outside every pool would not be allocatable — the pool
      was widened from `.21-.30` to `.20-.30` for exactly this reason. Dev has the same shape
      (`GATEWAY_VIP` `.53` = first of `.53-.60`).
    
  • Reserve all of 192.168.2.9 and .20-.30 outside any DHCP range on the prod LAN before the build, and confirm nothing else on the network already answers on them.

  • Resolver: SECOND UPSTREAM IS AN OPEN DECISION — blocks node-baseline.yml --tags dns. Node 1 has a single IPv4 nameserver, 192.168.2.1, which is also the LAN gateway. A single upstream is a known SPOF that has already bitten this project — it broke containerd image pulls and CoreDNS forwarding on dev.

    The MECHANISM is now in the repo and needs no further work: the `dns`-tagged block in
    `roles/node_baseline` detects whether a node uses systemd-resolved (dev: writes
    `/etc/systemd/resolved.conf.d/99-k3s-dns.conf`, restarts resolved) or a directly-managed
    `/etc/resolv.conf` (prod's shape: writes the file, refusing if resolvconf/NetworkManager
    owns it), and configures the ordered upstream list either way. The earlier
    `fix/node-dns-resilient-upstream` branch was **dropped, not merged** — it wrote a netplan
    drop-in and ran `netplan apply`, and netplan is not installed on these Debian 13 trixie
    nodes, so it would have broken `node-baseline.yml` on every host.
    
    What is still MISSING is the VALUE. `group_vars/k3s_prod/vars.yml` sets
    `node_baseline_dns_servers` to `192.168.2.1` followed by the deliberately invalid
    `BLOCKED-pending-second-upstream-decision-see-PROD-PROVISIONING-md-4`, and the role's assert
    stops the play on it before writing anything. Choosing the second upstream is a **network
    decision, not a default the role may take**: a public resolver (`8.8.8.8`, `1.1.1.1`) would
    resolve reliably but would also bypass any local zone and any filtering the gateway applies.
    Decide between — and record the choice HERE, in the same change that edits the group_vars:
    - a second on-LAN resolver on `192.168.2.x`;
    - the dev-side PiHole `192.168.1.18`, **if** prod can actually route to it (unverified —
      prod sits on the workstation side of the pfSense boundary);
    - an explicit, written-down acceptance of a public resolver as fallback-only.
    
    Also decide whether node 1's current IPv6 nameservers (`2001:4860:4860::8888` / `::8844`)
    are kept: the direct-file write path replaces `/etc/resolv.conf` with exactly the listed
    servers, so keeping them means listing them explicitly.
    `node_baseline_dns_search` is `[]` (no search domain, node 1's behaviour today) until prod's
    local domain is decided.
    
  • Confirm the prod LAN's relationship to the dev LAN (192.168.1.x) and to the pfSense NAT — prod on 192.168.2.x sits on the workstation side of the boundary dev lives behind.

5. Access (per node) — blocks all Ansible

  • k3s user with the home_network SSH key. Working on node 1.
  • Password-protected sudo, driven by Ansible become + a vaulted password. Prod does NOT use NOPASSWD sudo (operator decision, 2026-08-31). Dev nodes do; prod deliberately keeps the sudo password in place and supplies it to Ansible as an ansible-vault-encrypted var, exactly like the existing hypervisor and proxmox_hosts groups: inventory/group_vars/k3s_prod/ README.md how to (re)create the vault — committed vault.yml ansible_become_password: "..." — committed, ENCRYPTED The passphrase that decrypts it lives outside the repo at ~/.config/home-k3s/ansible-vault-pass (ansible.cfg :: vault_password_file), so plays still run unattended without a plaintext secret ever touching git. bash ansible-vault create inventory/group_vars/k3s_prod/vault.yml # ansible_become_password: ... Prod nodes must therefore set ansible_become: true in their group_vars and must not inherit any passwordless-sudo assumption from group_vars/all.yml.
  • Drive health baseline (§2). Do not hand-install the tooling — package installation is the node_baseline role's job, never a manual apt-get on a node (operator ruling, 2026-08-31; same click-ops-never principle as the rest of the repo). smartmontools is part of node_baseline_packages, so it arrives with the baseline play — but a full baseline would hit the disk tasks §2 has not decided yet. Run the packages-only baseline instead (the disks-tagged tasks, including the BLOCKED-device assert, are not selected at all, so the placeholder device paths are never even templated): bash cd infra/ansible ansible-playbook playbooks/node-baseline.yml \ -e k3s_hosts=k3s_prod --tags packages --limit k3s-prod-1 (Needs group_vars/k3s_prod/vault.yml to exist first — the become password above.) Reading the drive is then: bash sudo smartctl -a /dev/sda # Power_On_Hours, Percent_Lifetime_Remaining, reallocated sectors Record the result in §2 and close the layout decision in the same change that replaces the two node_baseline_*_device placeholders.

6. Ansible baseline & cluster join

Reuses the dev roles unchanged — that reuse is R-ENV-02. Only inventory and group_vars differ, plus a target-group override on the command line.

How prod is targeted (done, 2026-08-31)

Every node-host play used to hardcode the literal dev groups k3s_servers / k3s_primary / k3s_secondary, so nothing here could select prod at all. Two knobs now close that, deliberately kept separate because Ansible resolves them at different times:

Layer Knob Set via
Which hosts a play runs on k3s_hosts, k3s_primary_hosts, k3s_secondary_hosts (each defaults to the dev group) -e extra vars only — a play's hosts: is templated before any host exists, so group_vars is not readable there
Which group a role means by "my primary" / "my servers" k3s_primary_group, k3s_servers_group, cluster_kubeconfig_name group_vars — dev in all.yml, prod in k3s_prod/vars.yml; no per-run flag

So roles/k3s_server finds the prod --cluster-init founder, builds the prod join target and tls-san list, and roles/cilium fetches the prod kubeconfig, with no role fork. Running with no extra vars is byte-for-byte the dev behaviour it always had (verified by a before/after --list-hosts diff on every playbook). Full detail: infra/ansible/README.md → Targeting prod.

  • Add a k3s_prod inventory group (k3s_prod_primary / k3s_prod_secondary). Prod is reached directly on the LAN — no NAT port-forward hop, unlike dev's 192.168.2.102:225x mapping. (Nodes 2/3 stay commented out until they are physically on the bench.)
  • inventory/group_vars/k3s_prod/vars.yml: kube_vip_address (192.168.2.9), cluster_controller_api_server, k3s_api_host, the group-name overrides above — and the §2 device overrides for node_baseline_longhorn_device / node_baseline_etcd_device, which are still BLOCKED placeholders.
  • inventory/group_vars/k3s_prod/vault.yml — the vaulted ansible_become_password (§5). Until it exists no prod play can escalate, and --check against prod cannot work either.
  • Run the packages-only baseline first, to unblock the §2 drive-health read: bash ansible-playbook playbooks/node-baseline.yml -e k3s_hosts=k3s_prod --tags packages
  • Run the full playbooks/node-baseline.yml -e k3s_hosts=k3s_prod → packages, kernel modules, sysctls, iscsid, data-disk filesystems + mounts. Blocked until §2 is decided: it asserts on the placeholder device paths and stops. (qemu-guest-agent is a no-op on bare metal — the role already only starts it when the virtio channel exists, so it degrades cleanly.)
  • Run playbooks/k3s.yml -e k3s_primary_hosts=k3s_prod_primary -e k3s_secondary_hosts=k3s_prod_secondary → HA embedded etcd, flannel/kube-proxy/Traefik/servicelb disabled. Only once all three nodes are present — see §8.
  • Run playbooks/kube-vip.yml -e k3s_hosts=k3s_prod → control-plane VIP (192.168.2.9) on the prod LAN.
  • Run playbooks/cilium.yml -e k3s_hosts=k3s_prod → CNI at bootstrap; Flux's HelmRelease adopts it afterwards. The bootstrap values and the HelmRelease must stay in parity (kubeProxyReplacement, k8sServiceHost/Port) or the two layers fight over CNI config (docs/02). Note the prod kubeconfig is fetched to .cache/prod.kubeconfig, never over the dev one the dev container exports as $KUBECONFIG.
  • Run playbooks/verify.yml -e k3s_hosts=k3s_prod.
  • playbooks/flux-bootstrap.yml -e k3s_hosts=k3s_prod retargets but is not yet correct: roles/flux_bootstrap shells out to bootstrap/flux/bootstrap.sh, which bootstraps --path=clusters/dev. Prod needs --path=clusters/prod — a bootstrap/ change, not a target-group change. Tracked with the other repo blockers in §7.
  • Decide whether prod runs a VPN egress gateway node (dev uses k3s-dev-3, ADR-0015). playbooks/vpn.egress.gateway.yml takes -e vpn_egress_gateway_hosts=<group>, but there is deliberately no prod egress group in the inventory yet, and it would need its own vaulted PIA credentials — the existing vault is scoped to the dev group.

7. Repo blockers — prod cannot be reconciled until these land

clusters/prod is design-only today and would build wrong. R-ENV-02 promises dev and prod differ only by cluster-vars values; in practice dev LAN addresses are hardcoded into base manifests:

Hardcoded value Where Prod needs
k8sServiceHost: 192.168.1.50 platform/cilium/helmrelease.yaml:50, mirrored in values.yaml:16 prod primary node IP
LB pool 192.168.1.53–.60 platform-config/cilium/l2-ip-pool.yaml:15 a prod-LAN pool
192.168.1.55 (crafty) platform/crafty/service-l4.yaml prod-LAN address
192.168.1.54 (UniFi VM) apps/vms/unifi/50-service-l4.yaml prod-LAN address
192.168.1.9:9000 (S3 backup) platform/keycloak/postgres-cluster.yaml, apps/wave-0/{nextcloud,semaphore}-db.yaml reachable prod backup target
  • Tokenize each into a cluster-vars knob with a base default, then set the value in both overlays. Adding a knob before referencing ${KNOB} is the sanctioned mechanism (see the header comment in clusters/base/cluster-vars.yaml). platform, platform-config, the app waves, apps-vms and crafty all already carry postBuild.substituteFrom: cluster-vars, so the seam exists.
  • clusters/prod must set GATEWAY_VIP. It currently doesn't, so prod would inherit the base default 10.73.0.240 — an address from the retired libvirt network. The base file's own comment flags this as owed "when hardware is built."
  • Dev overlay sets every new knob to today's exact value so rendered dev output is byte-identical and the live cluster sees zero drift. Verify with make -C ci render-golden.
  • clusters/prod is NOT bootstrappable as-is — three gaps, found 2026-09-01 while landing the dependsOn fix. Only the first is now closed: - [x] Root Kustomization — clusters/prod/sync.yaml authored, mirroring dev. This became load-bearing, not cosmetic: clusters/base/platform.yaml now carries dependsOn: [flux-system], so without a root object on prod, platform would block forever on a dependency that does not exist and nothing downstream would reconcile. - [x] SOPS decryption — DONE. Operator decision 2026-09-01: prod uses the SAME age key as dev. Eight decryption: {provider: sops, secretRef: sops-age} patches mirror dev exactly. The sops-age Secret is still created OUT OF BAND on the prod cluster (bootstrap/sops/install-age-key.sh) — the overlay references it by name only. - [~] GitRepository source — BRANCH settled, URL still blocked. Operator decision 2026-09-01: prod tracks main, the same branch as dev, because dev is temporary and will be decommissioned once prod is stable. Recorded consequence: once prod is live, every merge to main reconciles BOTH clusters — no promotion step, no soak window. The URL is patched in but cannot work on a cold prod cluster, for two independent reasons found 2026-09-01: 1. Self-hosting circularity — Gitea runs on the DEV cluster, the one slated for decommission. Gitea must move to prod (or off-cluster) BEFORE dev is retired, or prod loses its source of truth. This is the decommission plan's first task, not its last. 2. Split-horizon sends it to the wrong place — coredns-custom answers the entire home.keithjackson.dev zone with ${GATEWAY_VIP}, which on prod is 192.168.2.20: prod's OWN gateway, where no Gitea listens. Prod's Flux would resolve gitea.home.keithjackson.dev to itself and never reach a repository. Bring-up needs a TEMPORARY source (bootstrap host-Gitea, or an off-cluster mirror) and a cutover once Gitea runs on prod — the same sequence docs/05 describes for dev's own Phase-6 cutover.
  • Confirm prod's backup target: dev's S3 (versitygw on the Proxmox host, 192.168.1.9) is on the dev side of the network. Off-cluster backup is DR-critical (R-STATE-03).

8. Build sequence (operator decision, 2026-08-31: wait for all three nodes)

Node 1 is baselined now; the cluster is not initialized until nodes 2 and 3 are on the bench. This keeps prod spec-conformant (3-node HA embedded etcd) from its first boot, avoids a single-server-etcd window, and avoids a later member-add dance.

  1. Per-node §1–§5 on each of the three boxes.
  2. §7 repo work lands on main with the gate green.
  3. node-baseline → k3s (all three) → kube-vip → cilium.
  4. flux bootstrap ... --path=clusters/prod.
  5. Conformance against prod (§9).

9. Exit criteria (Phase 7)

  • Prod runs the same config as dev via the prod overlay, no base edits (R-ENV-02).
  • Node destroy/rebuild from IaC + Ansible without data loss (R-ENV-01, R-STATE-01).
  • Full automated prod DR drill (R-STATE-03) — definition-of-done.md requires this for prod specifically.
  • Monitoring and alerts live on prod.
  • The conformance suite passes green against the prod cluster, not just dev (R-TEST-03).