THE MODEL WAS WRONG AND MY CHECK WITH IT. A live counter-example: k3s-prod-2 after its power
cycle shows MEMATTR=0xbeeb0018 and 'Failed to map ... @ 0xbeeb0018' — the SAME address and SAME
line as both of its 2.6 GiB boots — with MemTotal 15857732 kB, i.e. 15.1 GiB of 16 GB. FULL
MEMORY. The check reported FAIL 'THIS NODE HAS LOST MEMORY TO THE BUG' on a healthy node while
memory.physical_total correctly PASSed at 4.2%. The two checks contradicted each other.
REFINED MECHANISM — two kernel functions were conflated:
efi_memattr_init() does the memblock_reserve(). Catastrophic loss needs tbl_size NEGATIVE
(signed int -> sign-extended -> clamped to PHYS_ADDR_MAX). A garbage-but-POSITIVE tbl_size
reserves a modest wrong amount and costs nothing noticeable.
efi_memattr_apply_permissions() does the later memremap(), and THAT is what prints
'Failed to map'. It fails for ANY sufficiently wrong size, negative or merely large-positive.
So the line proves the table was corrupt AND TRUSTED, not that memory was lost. The cost is set
by the garbage VALUE, which is why one address gave 2.6 GiB twice and 15.1 GiB once.
THIS ALSO REFUTES THE ADDRESS->OUTCOME HYPOTHESIS OUTRIGHT — not untested, disproven.
STRUCTURAL FIX so the contradiction cannot recur: the shortfall is computed ONCE into a shared
fact (node_health_mem_shortfall) with worst-wins sub-verdicts; memory.physical_total IS that
verdict and firmware.efi_memattr READS it, measuring nothing itself. FAIL is gated on the shared
verdict. 'Failed to map' + normal memory is now WARN ('the bug fired and this boot survived it').
No honesty guard was weakened; one was strengthened (the measurement clause falls back to the DIMM
shortfall when zoneinfo is unreadable, and only claims 'could NOT be measured' when neither was
read). All five paths incl. the two unproducible-live SKIPs exercised against synthetic facts.
Verdicts: prod-1 WARN, prod-2 WARN (was FAIL), prod-3 PASS, dev unaffected.
SECOND FAULT, arguably worse for prod: NODE 2 HANGS ON A WARM REBOOT, STAYING POWERED. Its
journal ends cleanly mid-shutdown ('eno1: NIC Link is Down') then stops; the box sat powered but
off-LAN for ~38 min until the operator held the power button. A node that cannot survive an
unattended warm reboot cannot be rolled in an HA cluster, and node_health cannot see a machine
that is off the network. Leading candidate: node 2 is the ONLY node with 'Recover OS after Boot
Failure = Enable' — promoted from 'coincidence' in the BIOS diff to a live availability defect.
The reboot survey is NOT viable unattended on node 2 until this is understood.
SURVEY RESULTS (40 boots): prod-1 0/20, prod-3 0/20, prod-2 0 ROUNDS (hung on its first reboot),
pooled 0/40 -> p(bad) 95% CI 0.000-0.088. NOT elimination: 0/20 still permits 17% per node, and
node 2's prior 2-of-3 is unchanged. What it did establish: addresses are node-specific and highly
concentrated (node 1 used 3 distinct addresses in 20 boots, 15 at one; no address ever shared
between nodes); MEMATTR -> parse was a PERFECT function across all 7 repeated addresses over 37
boots; and the corrupting bytes are stable PER MACHINE (node 1 always 1030, node 3 always
1463964749), so the 'shared OS boot chain' inference needs refining.
Adds playbooks/memattr-survey.yml + roles/memattr_survey — reboots opt-in, resumable, artifacts
gitignored. Documents an Ansible defect worth knowing repo-wide: a looped include_tasks under the
default 'linear' strategy is flattened per host, so hosts run SERIALLY; the first attempt rebooted
node 1 twenty times while the others idled. Fixed with strategy: free + a forks preflight assert.
Serves: R-ENV-01, R-ENV-03, R-OBS-04, R-TEST-02. Task: T-7.1.
Co-Authored-By: Claude Opus 5 (1M context) <[email protected]>
982 lines
58 KiB
YAML
982 lines
58 KiB
YAML
---
|
|
# Turn raw facts into explicit, named checks. Every check is one of:
|
|
#
|
|
# PASS measured, and within threshold
|
|
# WARN measured, outside the warn threshold — worth a human look
|
|
# FAIL measured, outside the fail threshold — do not put production state here
|
|
# SKIP NOT measured, with the reason attached (missing root, missing tool, sensor not
|
|
# present on this hardware). A SKIP is an honest "unknown" and is NEVER rendered
|
|
# as a pass — this repo's discipline is absolute on that point.
|
|
# INFO measured, no pass/fail semantics (inventory: firmware, uptime, CPU scaling)
|
|
#
|
|
# All thresholds come from node_health_thresholds (defaults/main.yml) so retuning never
|
|
# means editing logic here.
|
|
|
|
- name: Derive intermediate values used by several checks
|
|
ansible.builtin.set_fact:
|
|
# Every temperature the box exposes, from both thermal zones and hwmon chips.
|
|
# `select('number')` drops any sensor that returned null (unreadable/absent).
|
|
node_health_temps_c: >-
|
|
{{ ((node_health_facts.thermal.zones | map(attribute='temp_c') | list)
|
|
+ (node_health_facts.thermal.hwmon | map(attribute='temps') | flatten
|
|
| map(attribute='temp_c') | list)) | select('number') | list }}
|
|
# Filesystems, worst-first by percentage used / inodes used.
|
|
node_health_mounts_by_use: >-
|
|
{{ node_health_facts.storage.mounts | selectattr('used_pct', 'number')
|
|
| sort(attribute='used_pct') | reverse | list }}
|
|
node_health_mounts_by_inode: >-
|
|
{{ node_health_facts.storage.mounts | selectattr('inodes_used_pct', 'number')
|
|
| sort(attribute='inodes_used_pct') | reverse | list }}
|
|
# Physical NICs that are actually up. Virtual plumbing was already excluded by the
|
|
# collector; `virtual` here catches bonds/VLANs the regex let through.
|
|
node_health_nics_up: >-
|
|
{{ node_health_facts.network.interfaces
|
|
| selectattr('operstate', 'equalto', 'up') | list }}
|
|
# Devices that could actually BECOME a dedicated Longhorn or etcd volume: no
|
|
# partitions, no whole-device filesystem, nothing mounted from them. All three
|
|
# conditions matter — node_baseline formats the data disks with no partition table at
|
|
# all (mkfs straight onto /dev/vdb, mounted by LABEL), so "no partitions" alone would
|
|
# nominate a node's live Longhorn disk for reformatting. iSCSI/FC volumes were already
|
|
# split out by the collector for the same reason. On a single-disk node this list is
|
|
# empty — precisely the finding that blocks PROD-PROVISIONING.md §2.
|
|
node_health_free_devices: >-
|
|
{{ node_health_facts.storage.disks
|
|
| selectattr('partitions', 'equalto', [])
|
|
| selectattr('fstype', 'none')
|
|
| selectattr('mountpoints', 'equalto', [])
|
|
| list }}
|
|
vars:
|
|
ansible_become: false
|
|
|
|
- name: Assess — privilege escalation (gates every root-only check below)
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'access.privilege',
|
|
'title': 'Privilege escalation (become) for root-only checks',
|
|
'status': ('INFO' if node_health_root_available | bool else 'SKIP'),
|
|
'detail': node_health_root_skip_reason }] }}"
|
|
|
|
# --- Storage ------------------------------------------------------------------------
|
|
# SMART VERDICTS — READ defaults/main.yml's SMART threshold block BEFORE EDITING THIS.
|
|
# Short version: this check judges a drive on the signals smartctl(8) itself defines as
|
|
# vendor-independent (the drive's own overall-health verdict; NORMALISED value vs the
|
|
# MANUFACTURER'S OWN threshold, via smartctl's `when_failed`; and the ATA-standard error
|
|
# counters 197/198/187/199 whose raw meaning is a plain event count everywhere, plus NVMe's
|
|
# structured health log). Vendor raw counts are reported with their numbers and can raise a
|
|
# WARN, but they can never produce a FAIL — because their units are vendor-defined and
|
|
# reading one as if it were a portable sector count is exactly the defect this replaces.
|
|
- name: Assess — SMART per physical disk
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'storage.smart.' ~ item.kname,
|
|
'title': 'SMART health — ' ~ item.path ~ ' (' ~ (item.model | default('unknown model')) ~ ')',
|
|
'status': smart_status,
|
|
'detail': smart_detail }] }}"
|
|
loop: "{{ node_health_facts.storage.disks }}"
|
|
loop_control:
|
|
label: "{{ item.path }}"
|
|
vars:
|
|
ansible_become: false
|
|
th: "{{ node_health_thresholds }}"
|
|
disk_smart: "{{ (node_health_smart | selectattr('path', 'equalto', item.path) | list | first) | default({}) }}"
|
|
|
|
# --- Sub-verdicts. Each is SKIP unless the number behind it was actually read; a SKIP is
|
|
# an honest "unknown" and never contributes a PASS. ------------------------------------
|
|
|
|
# 1. The drive's own overall-health self-assessment. Vendor-independent by construction.
|
|
s_health: >-
|
|
{{ 'SKIP' if (disk_smart.passed is not defined or disk_smart.passed is none)
|
|
else ('PASS' if disk_smart.passed else 'FAIL') }}
|
|
# 2. NVMe critical warning bitfield (spare below threshold, media in read-only, etc.).
|
|
s_nvme_crit: >-
|
|
{{ 'SKIP' if (disk_smart.nvme_critical_warning is not defined or disk_smart.nvme_critical_warning is not number)
|
|
else ('PASS' if disk_smart.nvme_critical_warning | int == 0 else 'FAIL') }}
|
|
# 3. THE portable per-attribute failure signal: normalised value at or below the
|
|
# threshold the MANUFACTURER set for that attribute on that model. Pre-fail failing
|
|
# now = FAIL. Old_age failing now, or anything that failed in the past, = WARN.
|
|
s_thresh: >-
|
|
{{ 'SKIP' if not (disk_smart.thresholds_present | default(false))
|
|
else ('FAIL' if (disk_smart.failing_now_prefail | default([]) | length) > 0
|
|
else ('WARN' if ((disk_smart.failing_now | default([]) | length) > 0
|
|
or (disk_smart.failed_past | default([]) | length) > 0)
|
|
else 'PASS')) }}
|
|
# 4. ATA-standard hard-error counters. 197 pending; 198/187 + NVMe media_errors are
|
|
# uncorrectable reads — data the drive could NOT return. Same meaning on every drive.
|
|
s_pending: >-
|
|
{{ 'SKIP' if (disk_smart.pending_sectors is not defined or disk_smart.pending_sectors is not number)
|
|
else ('FAIL' if disk_smart.pending_sectors | int >= th.smart_pending_fail
|
|
else ('WARN' if disk_smart.pending_sectors | int >= th.smart_pending_warn else 'PASS')) }}
|
|
uncorr_values: >-
|
|
{{ [disk_smart.offline_uncorrectable | default(none),
|
|
disk_smart.reported_uncorrect | default(none),
|
|
disk_smart.nvme_media_errors | default(none)] | select('number') | list }}
|
|
s_uncorr: >-
|
|
{{ 'SKIP' if (uncorr_values | length) == 0
|
|
else ('FAIL' if (uncorr_values | max) >= th.smart_uncorrectable_fail
|
|
else ('WARN' if (uncorr_values | max) >= th.smart_uncorrectable_warn else 'PASS')) }}
|
|
# 5. 199 CRC — SATA link integrity (cable/backplane), not media. WARN only: the counter
|
|
# never resets, so one historic bad seating must not condemn the node forever.
|
|
s_crc: >-
|
|
{{ 'SKIP' if (disk_smart.crc_errors is not defined or disk_smart.crc_errors is not number)
|
|
else ('WARN' if disk_smart.crc_errors | int >= th.smart_crc_warn else 'PASS') }}
|
|
# 6. Wear, from the NORMALISED lifetime indicator — a percentage by definition.
|
|
life_rem: "{{ disk_smart.lifetime_remaining_pct | default(none) }}"
|
|
life_used: "{{ (100 - (life_rem | int)) if (life_rem is number) else none }}"
|
|
s_life: >-
|
|
{{ 'SKIP' if (life_rem is not number)
|
|
else ('FAIL' if life_rem | int <= th.smart_lifetime_remaining_fail_pct
|
|
else ('WARN' if (life_rem | int <= th.smart_lifetime_remaining_warn_pct
|
|
or life_used | int >= th.smart_life_used_pct_warn)
|
|
else 'PASS')) }}
|
|
# 7. Reallocation ACTIVITY. Portable evidence first (196 event count, and the grown
|
|
# bad-block counter smartctl's drivedb named for this model). Only if neither exists
|
|
# do we fall back to attribute 5's raw — and then ONLY to say "nonzero, so something
|
|
# was remapped", which is portable, never to interpret its magnitude, which is not.
|
|
remap_evidence: >-
|
|
{{ [disk_smart.realloc_events | default(none),
|
|
disk_smart.grown_bad_blocks | default(none)] | select('number') | list }}
|
|
realloc_raw: "{{ (disk_smart.realloc_attr | default({}, true)).get('raw', {}).get('value', none) }}"
|
|
s_remap: >-
|
|
{{ ('WARN' if (remap_evidence | max) >= th.smart_realloc_events_warn else 'PASS')
|
|
if (remap_evidence | length) > 0
|
|
else (('WARN' if realloc_raw | int > 0 else 'PASS') if realloc_raw is number else 'SKIP') }}
|
|
# 8. Endurance stress — erase/program failures are NAND wearing out under the FTL.
|
|
s_erase: >-
|
|
{{ 'SKIP' if (disk_smart.erase_fail_count is not defined or disk_smart.erase_fail_count is not number)
|
|
else ('WARN' if disk_smart.erase_fail_count | int >= th.smart_erase_fail_warn else 'PASS') }}
|
|
s_program: >-
|
|
{{ 'SKIP' if (disk_smart.program_fail_count is not defined or disk_smart.program_fail_count is not number)
|
|
else ('WARN' if disk_smart.program_fail_count | int >= th.smart_program_fail_warn else 'PASS') }}
|
|
# 9. Unexpected power loss. On a consumer SSD with no power-loss protection each one is
|
|
# an opportunity for a torn or lost in-flight write — which is precisely the guarantee
|
|
# etcd's fsync contract depends on. Directly relevant to PROD-PROVISIONING.md Section 2.
|
|
s_ploss: >-
|
|
{{ 'SKIP' if (disk_smart.unexpected_power_loss is not defined or disk_smart.unexpected_power_loss is not number)
|
|
else ('WARN' if disk_smart.unexpected_power_loss | int >= th.smart_unexpected_power_loss_warn else 'PASS') }}
|
|
s_temp: >-
|
|
{{ 'SKIP' if (disk_smart.temperature_c is not defined or disk_smart.temperature_c is not number)
|
|
else ('FAIL' if disk_smart.temperature_c | int >= th.smart_temp_fail_c
|
|
else ('WARN' if disk_smart.temperature_c | int >= th.smart_temp_warn_c else 'PASS')) }}
|
|
# Worst sub-verdict wins. `select('in', ...)` preserves the order of the left-hand
|
|
# list, so the LAST survivor is the most severe present.
|
|
smart_status: >-
|
|
{{ (['PASS', 'WARN', 'FAIL'] | select('in', [s_health, s_nvme_crit, s_thresh, s_pending,
|
|
s_uncorr, s_crc, s_life, s_remap, s_erase, s_program, s_ploss, s_temp]) | list | last)
|
|
| default('SKIP', true) }}
|
|
|
|
# --- Detail. Every WARN/FAIL must arrive WITH the number that caused it; a verdict the
|
|
# operator cannot check is not much better than a wrong one. -------------------------
|
|
smart_findings: >-
|
|
{%- set n = namespace(l=[]) -%}
|
|
{%- if s_health == 'FAIL' -%}
|
|
{%- set _ = n.l.append('the drive reports its OWN overall-health self-assessment as FAILED') -%}
|
|
{%- endif -%}
|
|
{%- if s_nvme_crit == 'FAIL' -%}
|
|
{%- set _ = n.l.append('NVMe critical_warning=' ~ disk_smart.nvme_critical_warning ~ ' (non-zero)') -%}
|
|
{%- endif -%}
|
|
{%- for a in (disk_smart.failing_now_prefail | default([])) -%}
|
|
{%- set _ = n.l.append('Pre-fail attribute ' ~ a.id ~ ' ' ~ a.name ~ ' is AT OR BELOW its manufacturer threshold NOW (value='
|
|
~ a.value ~ ', thresh=' ~ a.thresh ~ ')') -%}
|
|
{%- endfor -%}
|
|
{%- for a in (disk_smart.failed_past | default([])) -%}
|
|
{%- set _ = n.l.append('attribute ' ~ a.id ~ ' ' ~ a.name ~ ' crossed its manufacturer threshold IN THE PAST (worst='
|
|
~ a.worst ~ ', thresh=' ~ a.thresh ~ ')') -%}
|
|
{%- endfor -%}
|
|
{%- if s_pending in ['WARN', 'FAIL'] -%}
|
|
{%- set _ = n.l.append('current pending sectors (197)=' ~ disk_smart.pending_sectors) -%}
|
|
{%- endif -%}
|
|
{%- if s_uncorr in ['WARN', 'FAIL'] -%}
|
|
{%- set _ = n.l.append('UNCORRECTABLE read errors — offline(198)=' ~ (disk_smart.offline_uncorrectable if disk_smart.offline_uncorrectable is number else 'n/a')
|
|
~ ', reported(187)=' ~ (disk_smart.reported_uncorrect if disk_smart.reported_uncorrect is number else 'n/a')
|
|
~ ', nvme media_errors=' ~ (disk_smart.nvme_media_errors if disk_smart.nvme_media_errors is number else 'n/a')) -%}
|
|
{%- endif -%}
|
|
{%- if s_crc == 'WARN' -%}
|
|
{%- set _ = n.l.append('SATA link CRC errors (199)=' ~ disk_smart.crc_errors ~ ' — cable/backplane, not media') -%}
|
|
{%- endif -%}
|
|
{%- if s_life in ['WARN', 'FAIL'] -%}
|
|
{%- set _ = n.l.append(life_used ~ '% of rated life CONSUMED (' ~ life_rem
|
|
~ '% remaining, from the normalised wear indicator)') -%}
|
|
{%- endif -%}
|
|
{%- if s_remap == 'WARN' and (remap_evidence | length) > 0 -%}
|
|
{%- set _ = n.l.append((remap_evidence | max) ~ ' grown bad block(s)/reallocation event(s)'
|
|
~ (' [196 events=' ~ disk_smart.realloc_events ~ ']' if disk_smart.realloc_events is number else '')
|
|
~ (' [grown failing blocks=' ~ disk_smart.grown_bad_blocks ~ ']' if disk_smart.grown_bad_blocks is number else '')) -%}
|
|
{%- elif s_remap == 'WARN' -%}
|
|
{%- set _ = n.l.append('the drive reports a non-zero reallocation attribute (5 raw=' ~ realloc_raw
|
|
~ '); its UNIT is vendor-defined, so the count is not interpreted here') -%}
|
|
{%- endif -%}
|
|
{%- if s_erase == 'WARN' -%}
|
|
{%- set _ = n.l.append('NAND erase failures=' ~ disk_smart.erase_fail_count) -%}
|
|
{%- endif -%}
|
|
{%- if s_program == 'WARN' -%}
|
|
{%- set _ = n.l.append('NAND program failures=' ~ disk_smart.program_fail_count) -%}
|
|
{%- endif -%}
|
|
{%- if s_ploss == 'WARN' -%}
|
|
{%- set _ = n.l.append('unexpected power losses=' ~ disk_smart.unexpected_power_loss
|
|
~ ' — a consumer SSD has no power-loss protection, so each one risks a torn or lost in-flight write') -%}
|
|
{%- endif -%}
|
|
{%- if s_temp in ['WARN', 'FAIL'] -%}
|
|
{%- set _ = n.l.append('temperature=' ~ disk_smart.temperature_c ~ 'C') -%}
|
|
{%- endif -%}
|
|
{{ n.l | join('; ') }}
|
|
# The raw value that started this. Shown ALWAYS when it is non-zero and contradicts the
|
|
# normalised reading, explicitly labelled as vendor-encoded and explicitly excluded from
|
|
# the verdict — so the next operator to see 61440 sees why it is not 61440 bad sectors.
|
|
realloc_raw_note: >-
|
|
{%- if realloc_raw is number and realloc_raw | int > 0 -%}
|
|
{%- set a = disk_smart.realloc_attr -%}
|
|
attribute 5 ({{ a.name }}) raw={{ realloc_raw }} normalised value={{ a.value }} vs thresh={{ a.thresh }}
|
|
{%- if (remap_evidence | length) > 0 and (remap_evidence | max) > 0
|
|
and realloc_raw | int != (remap_evidence | max) | int
|
|
and realloc_raw | int % (remap_evidence | max) | int == 0 -%}
|
|
{{ ' (= ' ~ (remap_evidence | max) ~ ' x ' ~ (realloc_raw | int // (remap_evidence | max) | int) ~ ')' }}
|
|
{%- endif -%}
|
|
. SMART raw values are VENDOR-DEFINED (smartctl(8): "entirely vendor-specific") and this
|
|
one is NOT a portable bad-sector count — it is reported as context and is NOT used for
|
|
the verdict. The normalised value/threshold pair beside it is the manufacturer's own
|
|
trip point and IS.
|
|
{%- endif -%}
|
|
smart_detail: >-
|
|
{{ ('not read — ' ~ node_health_root_skip_reason)
|
|
if not (node_health_root_available | bool)
|
|
else ('not read — smartmontools is not installed on this node; it ships with
|
|
roles/node_baseline (node_baseline_packages), which has not been run here.
|
|
This role never installs packages.')
|
|
if not (node_health_facts.tools.smartctl is truthy)
|
|
else ('smartctl ran but this device exposes no SMART data ('
|
|
~ (disk_smart.messages | default([]) | join('; ')) ~ ') — normal for virtio/VM disks')
|
|
if not (disk_smart.available | default(false))
|
|
else ('overall-health=' ~ ('PASSED' if disk_smart.passed else 'FAILED')
|
|
~ ', power_on_hours=' ~ (disk_smart.power_on_hours | default('?'))
|
|
~ ', power_cycles=' ~ (disk_smart.power_cycles | default('?'))
|
|
~ ', life_remaining=' ~ ((life_rem | string ~ '%') if life_rem is number else 'not reported')
|
|
~ ', pending(197)=' ~ (disk_smart.pending_sectors if disk_smart.pending_sectors is number else 'n/a')
|
|
~ ', offline_uncorrectable(198)=' ~ (disk_smart.offline_uncorrectable if disk_smart.offline_uncorrectable is number else 'n/a')
|
|
~ ', reported_uncorrect(187)=' ~ (disk_smart.reported_uncorrect if disk_smart.reported_uncorrect is number else 'n/a')
|
|
~ ', crc(199)=' ~ (disk_smart.crc_errors if disk_smart.crc_errors is number else 'n/a')
|
|
~ (('. NO attribute is at or below its manufacturer threshold; closest is '
|
|
~ disk_smart.prefail_closest.id ~ ' ' ~ disk_smart.prefail_closest.name
|
|
~ ' value=' ~ disk_smart.prefail_closest.value
|
|
~ ' vs thresh=' ~ disk_smart.prefail_closest.thresh)
|
|
if (s_thresh == 'PASS' and (disk_smart.prefail_closest | default(none)) is mapping) else '')
|
|
~ (('. FINDINGS: ' ~ smart_findings) if smart_findings | trim else '')
|
|
~ (('. CONTEXT: ' ~ realloc_raw_note) if realloc_raw_note | trim else '')) }}
|
|
|
|
- name: Assess — kernel-visible I/O errors per disk (no root needed)
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'storage.io_errors',
|
|
'title': 'Kernel I/O error counters on physical disks (SCSI/ATA layer)',
|
|
'status': io_status,
|
|
'detail': io_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
# ioerr_cnt/iotmo_cnt are readable WITHOUT root. They are not a substitute for SMART
|
|
# (no wear, no power-on hours, no reallocated sectors) but they are a real signal: a
|
|
# non-zero count means the kernel actually saw failed or timed-out commands on that
|
|
# device since boot.
|
|
counted: "{{ node_health_facts.storage.disks | selectattr('scsi_counters', 'mapping') | list }}"
|
|
err_total: >-
|
|
{{ (counted | map(attribute='scsi_counters.ioerr_cnt') | select('number') | list | sum)
|
|
+ (counted | map(attribute='scsi_counters.iotmo_cnt') | select('number') | list | sum) }}
|
|
io_status: >-
|
|
{{ 'SKIP' if (counted | length) == 0
|
|
else ('PASS' if err_total | int == 0 else 'WARN') }}
|
|
io_sum_done: "{{ counted | map(attribute='scsi_counters.iodone_cnt') | select('number') | list | sum }}"
|
|
io_sum_err: "{{ counted | map(attribute='scsi_counters.ioerr_cnt') | select('number') | list | sum }}"
|
|
io_sum_tmo: "{{ counted | map(attribute='scsi_counters.iotmo_cnt') | select('number') | list | sum }}"
|
|
# Aggregate here; the STORAGE section of the summary prints the per-disk counters.
|
|
io_detail: >-
|
|
{{ 'no disk exposes SCSI/ATA error counters (virtio or NVMe-only node)'
|
|
if (counted | length) == 0
|
|
else ((counted | map(attribute='kname') | join(', ')) ~ ': completed='
|
|
~ io_sum_done | string ~ ', errors=' ~ io_sum_err | string
|
|
~ ', timeouts=' ~ io_sum_tmo | string
|
|
~ ('. Non-zero errors are commands the kernel saw fail on that device
|
|
since boot. They are NOT proof of media failure (a rejected or
|
|
unsupported command during discovery counts too) and they cannot be
|
|
attributed without dmesg, which needs root.'
|
|
if err_total | int > 0 else '')) }}
|
|
|
|
- name: Assess — filesystem free space
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'storage.capacity',
|
|
'title': 'Filesystem free space (worst mount)',
|
|
'status': fs_status,
|
|
'detail': fs_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
th: "{{ node_health_thresholds }}"
|
|
worst: "{{ (node_health_mounts_by_use | first) | default({}) }}"
|
|
fs_status: >-
|
|
{{ 'SKIP' if (node_health_mounts_by_use | length) == 0
|
|
else ('FAIL' if worst.used_pct >= th.fs_used_pct_fail
|
|
else ('WARN' if worst.used_pct >= th.fs_used_pct_warn else 'PASS')) }}
|
|
fs_detail: >-
|
|
{{ 'no block-backed filesystem found' if (node_health_mounts_by_use | length) == 0
|
|
else (worst.mountpoint ~ ' ' ~ worst.used_pct | string ~ '% used ('
|
|
~ (worst.avail_bytes | int / 1073741824) | round(1) | string ~ ' GiB free of '
|
|
~ (worst.size_bytes | int / 1073741824) | round(1) | string ~ ' GiB)') }}
|
|
|
|
- name: Assess — filesystem inode headroom
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'storage.inodes',
|
|
'title': 'Filesystem inode headroom (worst mount)',
|
|
'status': in_status,
|
|
'detail': in_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
th: "{{ node_health_thresholds }}"
|
|
worst: "{{ (node_health_mounts_by_inode | first) | default({}) }}"
|
|
in_status: >-
|
|
{{ 'SKIP' if (node_health_mounts_by_inode | length) == 0
|
|
else ('WARN' if worst.inodes_used_pct >= th.inode_used_pct_warn else 'PASS') }}
|
|
in_detail: >-
|
|
{{ 'no filesystem reported inode usage' if (node_health_mounts_by_inode | length) == 0
|
|
else (worst.mountpoint ~ ' ' ~ worst.inodes_used_pct | string ~ '% of inodes used') }}
|
|
|
|
- name: Assess — data-disk layout (feeds PROD-PROVISIONING.md §2)
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'storage.layout',
|
|
'title': 'Physical disks and spare block devices for Longhorn/etcd',
|
|
'status': 'INFO',
|
|
'detail': layout_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
disks: "{{ node_health_facts.storage.disks }}"
|
|
attached: "{{ node_health_facts.storage.attached_volumes | default([]) }}"
|
|
layout_detail: >-
|
|
{{ (disks | length) | string ~ ' physical disk(s): '
|
|
~ (disks | map(attribute='kname') | join(', ')) ~ '. '
|
|
~ ((attached | length) | string ~ ' attached iSCSI/FC volume(s) excluded ('
|
|
~ (attached | map(attribute='kname') | join(', ')) ~ '). '
|
|
if (attached | length) > 0 else '')
|
|
~ ((node_health_free_devices | length) | string ~ ' device(s) with no partitions ('
|
|
~ (node_health_free_devices | map(attribute='kname') | join(', ')) ~ ')'
|
|
if (node_health_free_devices | length) > 0
|
|
else 'NO unpartitioned spare device — node_baseline_longhorn_device /
|
|
node_baseline_etcd_device have nothing to claim without repartitioning
|
|
or adding a drive') }}
|
|
|
|
# --- Memory -------------------------------------------------------------------------
|
|
- name: Assess — memory headroom
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'memory.available',
|
|
'title': 'Available memory',
|
|
'status': mem_status,
|
|
'detail': mem_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
th: "{{ node_health_thresholds }}"
|
|
m: "{{ node_health_facts.memory }}"
|
|
avail_pct: >-
|
|
{{ ((m.mem_available_kb | int) * 100.0 / (m.mem_total_kb | int)) | round(1)
|
|
if (m.mem_total_kb is number and m.mem_available_kb is number and m.mem_total_kb | int > 0)
|
|
else none }}
|
|
mem_status: >-
|
|
{{ 'SKIP' if avail_pct is not number
|
|
else ('FAIL' if avail_pct | float <= th.mem_available_pct_fail
|
|
else ('WARN' if avail_pct | float <= th.mem_available_pct_warn else 'PASS')) }}
|
|
mem_detail: >-
|
|
{{ '/proc/meminfo unreadable' if avail_pct is not number
|
|
else ((m.mem_total_kb | int / 1048576) | round(1) | string ~ ' GiB total, '
|
|
~ (m.mem_available_kb | int / 1048576) | round(1) | string ~ ' GiB available ('
|
|
~ avail_pct | string ~ '%)') }}
|
|
|
|
# --- THE ONE MEASUREMENT OF MEMORY THIS MACHINE CANNOT USE ----------------------------
|
|
# Measured HERE, once, because TWO checks need the answer: memory.physical_total (directly
|
|
# below) and firmware.efi_memattr (further down). Until 2026-09-03 each answered "did this
|
|
# machine lose memory?" from DIFFERENT evidence — this one from measurement, the memattr one
|
|
# from the presence of a kernel-log line — and they duly contradicted each other on the same
|
|
# host. k3s-prod-2 booted with `efi: memattr: Failed to map EFI Memory Attributes table @
|
|
# 0xbeeb0018` (the memattr check FAILed, asserting the node "HAS LOST MEMORY") while it was
|
|
# measurably using 15.1 GiB of its 16 GB DIMM (this check PASSed at 4.2% unmanaged). The
|
|
# measurement was right; the inference from the log line was wrong — the memattr block below
|
|
# has the refined mechanism.
|
|
#
|
|
# THE FIX IS STRUCTURAL, NOT A RE-WORDING. The shortfall is computed in exactly this one
|
|
# place and both checks read this fact: neither derives a shortfall of its own, and the
|
|
# memattr check may only report memory LOST when `status` here is FAIL. So the two cannot
|
|
# disagree about whether memory was lost — there is only one verdict on that question, and
|
|
# it is this one. Thresholds and their measured baselines: defaults/main.yml.
|
|
- name: Assess — measure memory the machine has and cannot use (once, shared by two checks)
|
|
ansible.builtin.set_fact:
|
|
node_health_mem_shortfall: "{{ {
|
|
'zones_pct': z_pct, 'zones_status': z_status,
|
|
'dimm_pct': d_pct, 'dimm_status': d_status, 'installed_kb': inst_kb,
|
|
'status': worst_status } }}"
|
|
vars:
|
|
ansible_become: false
|
|
th: "{{ node_health_thresholds }}"
|
|
z: "{{ node_health_facts.memory.zones }}"
|
|
dev: "{{ node_health_facts.memory.devices }}"
|
|
m: "{{ node_health_facts.memory }}"
|
|
|
|
# 1. /proc/zoneinfo: pages the kernel says are physically PRESENT, minus the pages it
|
|
# actually handed to the allocator (sum(managed) IS MemTotal). World-readable, no
|
|
# tools, identical on metal and in a VM — so this half is available almost always.
|
|
z_pct: "{{ z.unmanaged_pct if (z.available | bool) else none }}"
|
|
z_status: >-
|
|
{{ 'SKIP' if z_pct is not number
|
|
else ('FAIL' if z_pct | float >= th.mem_unmanaged_pct_fail
|
|
else ('WARN' if z_pct | float >= th.mem_unmanaged_pct_warn else 'PASS')) }}
|
|
|
|
# 2. SMBIOS type 17 vs MemTotal. Root-only and bare-metal-only, so it SKIPS on the dev
|
|
# VMs and wherever escalation is unavailable — with dmidecode's own reason attached,
|
|
# never as a zero DIMM count. Independent of the kernel's memory map entirely.
|
|
inst_kb: "{{ dev.installed_kb if (dev.available | bool) else none }}"
|
|
d_pct: >-
|
|
{{ (((inst_kb | int) - (m.mem_total_kb | int)) * 100.0 / (inst_kb | int)) | round(1)
|
|
if (inst_kb is number and m.mem_total_kb is number and (inst_kb | int) > 0)
|
|
else none }}
|
|
d_status: >-
|
|
{{ 'SKIP' if d_pct is not number
|
|
else ('FAIL' if d_pct | float >= th.mem_dimm_shortfall_pct_fail
|
|
else ('WARN' if d_pct | float >= th.mem_dimm_shortfall_pct_warn else 'PASS')) }}
|
|
|
|
# Worst sub-verdict wins; SKIP only when NEITHER measurement was obtained — two
|
|
# SKIPs must never add up to a PASS.
|
|
worst_status: >-
|
|
{{ (['PASS', 'WARN', 'FAIL'] | select('in', [z_status, d_status]) | list | last)
|
|
| default('SKIP', true) }}
|
|
|
|
# THE CAUSE-INDEPENDENT MEMORY-LOSS CHECK: it reports the measurement above. Its sibling
|
|
# firmware.efi_memattr names the one cause we have actually hit here; this one asks the
|
|
# blunter question — "is this machine using the RAM it has?" — and answers it from two
|
|
# sources that share NOTHING with the kernel log, so a future firmware, kernel or hypervisor
|
|
# losing memory for some other reason still shows up.
|
|
- name: Assess — usable memory vs the memory this machine physically has
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'memory.physical_total',
|
|
'title': 'Usable memory vs installed/present memory (independent of the kernel log)',
|
|
'status': phys_status,
|
|
'detail': phys_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
ms: "{{ node_health_mem_shortfall }}"
|
|
z: "{{ node_health_facts.memory.zones }}"
|
|
dev: "{{ node_health_facts.memory.devices }}"
|
|
m: "{{ node_health_facts.memory }}"
|
|
# Straight from the shared measurement — this check re-derives nothing.
|
|
z_pct: "{{ ms.zones_pct }}"
|
|
inst_kb: "{{ ms.installed_kb }}"
|
|
d_pct: "{{ ms.dimm_pct }}"
|
|
phys_status: "{{ ms.status }}"
|
|
# What the kernel log says, IF it was read — quoted here only as attribution for the
|
|
# measured shortfall. The verdict above is the shared measurement and never depends on
|
|
# the log; firmware.efi_memattr reads that same verdict, so the two always agree.
|
|
phys_cause: >-
|
|
{{ ('. CAUSE: the kernel logged the EFI Memory Attributes table failure — see check
|
|
firmware.efi_memattr and infra/PROD-PROVISIONING.md §0b')
|
|
if (node_health_facts.klog.memattr_state | default('')) == 'failed_to_map'
|
|
else ('. The kernel log was NOT read here, so this shortfall is unattributed —
|
|
see check firmware.efi_memattr')
|
|
if not (node_health_facts.klog.available | bool)
|
|
else '' }}
|
|
phys_detail: >-
|
|
{{ (('present ' ~ ((z.present_kb | int) / 1048576) | round(1) | string ~ ' GiB, managed '
|
|
~ ((z.managed_kb | int) / 1048576) | round(1) | string ~ ' GiB — '
|
|
~ z_pct | string ~ '% of the RAM the kernel memory map reports as physically PRESENT
|
|
was never handed to the allocator (/proc/zoneinfo)')
|
|
if z_pct is number
|
|
else ('present-vs-managed pages NOT read — ' ~ (z.reason | default('no reason recorded', true))))
|
|
~ '. '
|
|
~ (('SMBIOS reports ' ~ ((inst_kb | int) / 1048576) | round(1) | string ~ ' GiB installed across '
|
|
~ dev.populated_slots | string ~ ' of ' ~ dev.slots | string ~ ' slot(s) ('
|
|
~ (dev.devices | selectattr('size_kb', 'number') | map(attribute='locator') | join(', '))
|
|
~ '); MemTotal is ' ~ ((m.mem_total_kb | int) / 1048576) | round(1) | string
|
|
~ ' GiB — a ' ~ d_pct | string ~ '% shortfall')
|
|
if d_pct is number
|
|
else ('installed DIMM capacity NOT read — ' ~ (dev.reason | default('no reason recorded', true))))
|
|
~ (('. A few percent is normal and expected — the kernel image, memmap, firmware
|
|
reservations and (on this platform) 64 MiB of graphics stolen memory.
|
|
A shortfall of this size is memory the machine HAS and cannot use')
|
|
if phys_status in ['WARN', 'FAIL'] else '')
|
|
~ (phys_cause if phys_status in ['WARN', 'FAIL'] else '') }}
|
|
|
|
- name: Assess — swap (kubelet requires it off)
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'memory.swap',
|
|
'title': 'Swap disabled (kubelet prerequisite)',
|
|
'status': swap_status,
|
|
'detail': swap_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
m: "{{ node_health_facts.memory }}"
|
|
swap_status: >-
|
|
{{ 'SKIP' if m.swap_total_kb is not number
|
|
else ('PASS' if m.swap_total_kb | int == 0 else 'WARN') }}
|
|
swap_detail: >-
|
|
{{ 'swap state unreadable' if m.swap_total_kb is not number
|
|
else ('no swap active' if m.swap_total_kb | int == 0
|
|
else ((m.swap_total_kb | int / 1048576) | round(2) | string
|
|
~ ' GiB swap active — roles/node_baseline runs swapoff and neutralises
|
|
the fstab entry; this node has not been baselined yet')) }}
|
|
|
|
- name: Assess — ECC / EDAC correctable errors
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'memory.ecc',
|
|
'title': 'ECC memory errors (EDAC correctable/uncorrectable counters)',
|
|
'status': ecc_status,
|
|
'detail': ecc_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
e: "{{ node_health_facts.memory.edac }}"
|
|
ecc_status: >-
|
|
{{ 'SKIP' if not (e.controllers_present | bool)
|
|
else ('FAIL' if (e.ue_total | int) > 0
|
|
else ('WARN' if (e.ce_total | int) > 0 else 'PASS')) }}
|
|
ecc_detail: >-
|
|
{{ ('no EDAC memory controller is bound (' ~ ('/sys/devices/system/edac/mc exists but is empty'
|
|
if e.sysfs_present | bool else 'no EDAC sysfs at all')
|
|
~ ') — this platform does not report ECC status. Non-ECC consumer RAM or a VM;
|
|
"no errors" CANNOT be confirmed on this hardware.')
|
|
if not (e.controllers_present | bool)
|
|
else ((e.controllers | length) | string ~ ' controller(s), correctable='
|
|
~ e.ce_total | string ~ ', uncorrectable=' ~ e.ue_total | string) }}
|
|
|
|
# --- CPU ----------------------------------------------------------------------------
|
|
- name: Assess — CPU thermal throttling
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'cpu.throttle',
|
|
'title': 'CPU thermal throttling since boot',
|
|
'status': thr_status,
|
|
'detail': thr_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
t: "{{ node_health_facts.cpu.throttle }}"
|
|
thr_status: >-
|
|
{{ 'SKIP' if t is none
|
|
else ('PASS' if ((t.core_throttle_count_total | int) + (t.package_throttle_count | int)) == 0
|
|
else 'WARN') }}
|
|
thr_detail: >-
|
|
{{ 'no thermal_throttle counters (VM guest or unsupported CPU)' if t is none
|
|
else ('core throttle events=' ~ t.core_throttle_count_total | string
|
|
~ ' (' ~ t.core_throttle_total_time_ms | string ~ ' ms), package events='
|
|
~ t.package_throttle_count | string) }}
|
|
|
|
- name: Assess — CPU inventory and frequency scaling
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'cpu.inventory',
|
|
'title': 'CPU model, topology and frequency scaling',
|
|
'status': 'INFO',
|
|
'detail': cpu_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
c: "{{ node_health_facts.cpu }}"
|
|
cpu_detail: >-
|
|
{{ (c.model | default('unknown')) ~ ' — ' ~ (c.cpus | default('?')) ~ ' logical CPU(s), '
|
|
~ (c.sockets | default('?')) ~ ' socket(s) x ' ~ (c.cores_per_socket | default('?'))
|
|
~ ' core(s) x ' ~ (c.threads_per_core | default('?')) ~ ' thread(s); load '
|
|
~ (c.loadavg | default([]) | join(' ')) ~ '; '
|
|
~ ('governor=' ~ c.scaling.governor ~ ' driver=' ~ c.scaling.driver
|
|
~ ' cur=' ~ ((c.scaling.cur_khz | int) / 1000) | round | int | string ~ 'MHz'
|
|
~ ' max=' ~ ((c.scaling.max_khz | int) / 1000) | round | int | string ~ 'MHz'
|
|
if c.scaling is mapping else 'no cpufreq scaling exposed') }}
|
|
|
|
- name: Assess — hardware virtualisation (KubeVirt prerequisite, R-PLAT-03)
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'cpu.virtualisation',
|
|
'title': 'Hardware virtualisation available (VT-x/AMD-V + /dev/kvm)',
|
|
'status': virt_status,
|
|
'detail': virt_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
c: "{{ node_health_facts.cpu }}"
|
|
virt_status: >-
|
|
{{ 'PASS' if (c.hardware_virt_flag | bool and c.kvm_device | bool) else 'WARN' }}
|
|
virt_detail: >-
|
|
{{ 'vmx/svm flag=' ~ c.hardware_virt_flag | string ~ ', /dev/kvm='
|
|
~ c.kvm_device | string
|
|
~ (', lscpu Virtualization=' ~ c.virtualization if c.virtualization else '')
|
|
~ (', running as a guest of ' ~ c.hypervisor_vendor if c.is_virtual_guest | bool else '') }}
|
|
|
|
# --- Thermals -----------------------------------------------------------------------
|
|
- name: Assess — temperatures
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'thermal.max',
|
|
'title': 'Hottest reported sensor',
|
|
'status': temp_status,
|
|
'detail': temp_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
th: "{{ node_health_thresholds }}"
|
|
hottest: "{{ (node_health_temps_c | max) if (node_health_temps_c | length) > 0 else none }}"
|
|
temp_status: >-
|
|
{{ 'SKIP' if hottest is not number
|
|
else ('FAIL' if hottest | float >= th.temp_fail_c
|
|
else ('WARN' if hottest | float >= th.temp_warn_c else 'PASS')) }}
|
|
temp_detail: >-
|
|
{{ 'no thermal sensor exposed (typical in a VM)' if hottest is not number
|
|
else (hottest | string ~ 'C hottest of ' ~ (node_health_temps_c | length) | string
|
|
~ ' sensors; zones: '
|
|
~ (node_health_facts.thermal.zones
|
|
| map(attribute='type') | join(', ')) ) }}
|
|
|
|
# --- Pressure-stall (PSI) -----------------------------------------------------------
|
|
- name: Assess — pressure stall (CPU, memory, I/O)
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'pressure.' ~ item,
|
|
'title': 'PSI ' ~ item ~ ' — some avg60 (% of wall time stalled)',
|
|
'status': psi_status,
|
|
'detail': psi_detail }] }}"
|
|
loop: [cpu, memory, io]
|
|
vars:
|
|
ansible_become: false
|
|
th: "{{ node_health_thresholds }}"
|
|
psi: "{{ node_health_facts.pressure[item] | default(none) }}"
|
|
avg60: "{{ psi.some.avg60 | default(none) if psi is mapping else none }}"
|
|
psi_status: >-
|
|
{{ 'SKIP' if avg60 is not number
|
|
else ('FAIL' if avg60 | float >= th.psi_some_avg60_fail
|
|
else ('WARN' if avg60 | float >= th.psi_some_avg60_warn else 'PASS')) }}
|
|
psi_detail: >-
|
|
{{ '/proc/pressure/' ~ item ~ ' unavailable (kernel without CONFIG_PSI, or psi=0)'
|
|
if avg60 is not number
|
|
else ('some avg10=' ~ psi.some.avg10 | string ~ ' avg60=' ~ psi.some.avg60 | string
|
|
~ ' avg300=' ~ psi.some.avg300 | string
|
|
~ (' | full avg60=' ~ psi.full.avg60 | string if psi.full is defined else '')) }}
|
|
|
|
# --- Network ------------------------------------------------------------------------
|
|
- name: Assess — link state and speed
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'network.link',
|
|
'title': 'Physical NIC link state and negotiated speed',
|
|
'status': link_status,
|
|
'detail': link_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
th: "{{ node_health_thresholds }}"
|
|
up: "{{ node_health_nics_up }}"
|
|
slow: >-
|
|
{{ up | selectattr('speed_mbps', 'number')
|
|
| selectattr('speed_mbps', 'lt', th.nic_min_speed_mbps | int) | list }}
|
|
link_status: >-
|
|
{{ 'FAIL' if (up | length) == 0
|
|
else ('WARN' if (slow | length) > 0 else 'PASS') }}
|
|
link_detail: >-
|
|
{{ 'no physical interface is up' if (up | length) == 0
|
|
else (up | map(attribute='name') | zip(up | map(attribute='speed_mbps'))
|
|
| map('join', '=') | join('Mb/s, ') ~ 'Mb/s'
|
|
~ ' (driver ' ~ (up | map(attribute='driver') | join(', ')) ~ ')') }}
|
|
|
|
- name: Assess — link error counters
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'network.errors',
|
|
'title': 'NIC error counters since boot (rx/tx errors, CRC, carrier)',
|
|
'status': ('PASS' if err_total | int == 0 else 'WARN'),
|
|
'detail': err_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
up: "{{ node_health_nics_up }}"
|
|
err_keys: [rx_errors, tx_errors, rx_crc_errors, rx_frame_errors, rx_over_errors, tx_carrier_errors]
|
|
err_total: >-
|
|
{{ up | map(attribute='statistics') | map('dict2items') | flatten
|
|
| selectattr('key', 'in', err_keys) | map(attribute='value')
|
|
| select('number') | list | sum }}
|
|
drop_total: >-
|
|
{{ up | map(attribute='statistics') | map('dict2items') | flatten
|
|
| selectattr('key', 'in', ['rx_dropped', 'tx_dropped']) | map(attribute='value')
|
|
| select('number') | list | sum }}
|
|
err_detail: >-
|
|
{{ err_total | string ~ ' error(s), ' ~ drop_total | string ~ ' drop(s) across '
|
|
~ (up | map(attribute='name') | join(', ')) }}
|
|
|
|
# The collector reports the node's REAL upstreams: where /etc/resolv.conf holds only
|
|
# systemd-resolved's 127.0.0.53 stub (dev's shape) it asks resolved for the servers behind
|
|
# it, because counting the stub would be a permanent FALSE single-upstream WARN that no
|
|
# correct configuration could ever clear. When that lookup fails it reports null WITH a
|
|
# reason rather than a number — so the check SKIPs. A skip is honest; a WARN derived from
|
|
# an unknown is a fabricated verdict, and a PASS would be worse.
|
|
- name: Assess — DNS resolver redundancy
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'network.resolvers',
|
|
'title': 'Configured DNS upstreams (single upstream is a known SPOF here)',
|
|
'status': ('SKIP' if node_health_facts.network.nameservers is none
|
|
else ('PASS' if (ns4 | length) >= (node_health_thresholds.min_nameservers | int)
|
|
else 'WARN')),
|
|
'detail': ns_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
# `| default([], true)` only ever fires on the null (unreadable) path, where the
|
|
# counts below are unused because the status is already SKIP.
|
|
ns: "{{ node_health_facts.network.nameservers | default([], true) }}"
|
|
# Counted PER FAMILY on purpose. The outage this check exists for was a single IPv4
|
|
# upstream; IPv6 upstreams do not cover for it unless the node actually has working
|
|
# IPv6 egress, which this role cannot prove from sysfs alone. So the verdict keys off
|
|
# the IPv4 count and the detail shows the full picture.
|
|
ns4: "{{ ns | select('search', '^[0-9.]+$') | list }}"
|
|
ns6: "{{ ns | reject('search', '^[0-9.]+$') | list }}"
|
|
# Where the numbers came from — resolv.conf directly, or resolved behind the stub.
|
|
ns_src: "{{ node_health_facts.network.resolver_source | default('', true) }}"
|
|
ns_detail: >-
|
|
{{ ('not read — ' ~ (node_health_facts.network.resolver_unavailable_reason
|
|
| default('the collector recorded no reason', true))
|
|
~ '. The upstream count is UNKNOWN here — not zero, and not one.')
|
|
if node_health_facts.network.nameservers is none
|
|
else ((ns | length) | string ~ ' nameserver(s) — IPv4: '
|
|
~ (ns4 | join(', ') | default('none', true))
|
|
~ '; IPv6: ' ~ (ns6 | join(', ') | default('none', true))
|
|
~ (' (read via ' ~ ns_src ~ ')' if ns_src else '')
|
|
~ ('. Only ' ~ (ns4 | length) | string ~ ' IPv4 upstream: a single IPv4 upstream
|
|
already broke containerd image pulls and CoreDNS forwarding on dev. The fix
|
|
is the `dns`-tagged block in roles/node_baseline — set this environment
|
|
node_baseline_dns_servers (role defaults for dev, group_vars/k3s_prod for
|
|
prod) and re-run node-baseline.yml --tags dns. IPv6 upstreams only compensate
|
|
if the node has working IPv6 egress, which this check cannot verify.'
|
|
if (ns4 | length) < (node_health_thresholds.min_nameservers | int) else '')) }}
|
|
|
|
# --- OS / firmware ------------------------------------------------------------------
|
|
- name: Assess — pending reboot
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'os.reboot_required',
|
|
'title': 'Pending reboot flag',
|
|
'status': ('WARN' if node_health_facts.os.reboot_required | bool else 'PASS'),
|
|
'detail': ('/run/reboot-required present — a package upgrade needs a restart'
|
|
if node_health_facts.os.reboot_required | bool
|
|
else 'no reboot flagged') }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
|
|
- name: Assess — OS, kernel and uptime
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'os.inventory',
|
|
'title': 'OS, kernel and uptime',
|
|
'status': 'INFO',
|
|
'detail': os_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
o: "{{ node_health_facts.os }}"
|
|
os_detail: >-
|
|
{{ (o.pretty_name | default('unknown OS')) ~ ', kernel ' ~ (o.kernel | default('?'))
|
|
~ ', up ' ~ ((o.uptime_seconds | float / 86400) | round(2) | string) ~ ' day(s)' }}
|
|
|
|
- name: Assess — firmware / DMI inventory
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'firmware.inventory',
|
|
'title': 'Chassis, board and BIOS firmware',
|
|
'status': ('INFO' if node_health_facts.dmi.present | bool else 'SKIP'),
|
|
'detail': dmi_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
d: "{{ node_health_facts.dmi }}"
|
|
dmi_detail: >-
|
|
{{ 'no DMI table exposed (typical for some VMs/containers)' if not (d.present | bool)
|
|
else ((d.sys_vendor | default('?')) ~ ' ' ~ (d.product_name | default('?'))
|
|
~ ' / board ' ~ (d.board_name | default('?'))
|
|
~ ' / BIOS ' ~ (d.bios_vendor | default('?')) ~ ' '
|
|
~ (d.bios_version | default('?')) ~ ' (' ~ (d.bios_date | default('?')) ~ ')'
|
|
~ (' — serial numbers not read (root-only DMI fields)'
|
|
if d.product_serial is none else '')) }}
|
|
|
|
# --- EFI Memory Attributes Table ------------------------------------------------------
|
|
# THE AUTHORITATIVE WRITE-UP IS infra/PROD-PROVISIONING.md §0b. Do not re-derive it here;
|
|
# what follows is only what this check needs to be read correctly.
|
|
#
|
|
# HP R21 firmware publishes a CORRUPT EFI Memory Attributes Table, and Linux < 6.13 does
|
|
# not validate it before reserving memory from its contents. TWO DIFFERENT KERNEL FUNCTIONS
|
|
# are involved, and conflating them is what made this check wrong until 2026-09-03:
|
|
#
|
|
# efi_memattr_init() tbl_size = sizeof(*tbl) + num_entries * desc_size, then
|
|
# memblock_reserve(efi_mem_attr_table, tbl_size). tbl_size
|
|
# is a signed int. CATASTROPHIC LOSS REQUIRES IT TO BE
|
|
# NEGATIVE: a garbage product with bit 31 set sign-extends
|
|
# through phys_addr_t and memblock_cap_size() clamps it to
|
|
# PHYS_ADDR_MAX — everything above the table is reserved.
|
|
# A garbage-but-POSITIVE tbl_size reserves a modest, wrong
|
|
# amount and costs nothing measurable.
|
|
# efi_memattr_apply_permissions() memremap(efi_mem_attr_table, tbl_size, ...) later, and
|
|
# THIS is what prints "Failed to map". It fails for ANY
|
|
# sufficiently wrong tbl_size — negative OR merely large.
|
|
#
|
|
# SO: "Failed to map" PROVES the table was corrupt and the kernel trusted it. It does NOT
|
|
# prove memory was lost. The outcome depends on the VALUE of the garbage at that address on
|
|
# that boot, not on the address. k3s-prod-2 lost 13.3 GiB twice at 0xbeeb0018 and then, on
|
|
# 2026-09-03, booted with all 15.1 GiB at the SAME address and the SAME log line. That boot
|
|
# is the counter-example that falsified the old inference.
|
|
#
|
|
# THE VERDICT IS THEREFORE BASED ON MEASURED MEMORY, NOT ON THE LOG LINE:
|
|
#
|
|
# "Failed to map ... @ 0x..." the bug FIRED: corrupt table, trusted by the kernel.
|
|
# FAIL when the shared measurement (node_health_mem_shortfall) says memory is
|
|
# catastrophically missing — memory is lost NOW.
|
|
# WARN otherwise — this boot drew a survivable garbage value; the next may not.
|
|
# "Unexpected ... version <N>" version read > 2, so the kernel bailed out before
|
|
# reserving anything. WARN: exposed, and this boot took the safe path.
|
|
#
|
|
# The two lines are not "lucky vs unlucky" any more — there are three outcomes (bail-out,
|
|
# a trusted table that cost nothing, a trusted table that cost gigabytes) and only the
|
|
# measurement separates the last two. Never PASS on either line: the firmware is publishing
|
|
# a corrupt table and the draw is repeated on every boot.
|
|
#
|
|
# WHY THIS IS A CHECK AND NOT A NOTE IN A RUNBOOK: it is boot-to-boot NON-DETERMINISTIC,
|
|
# so it cannot be diagnosed once. It has to be measured on every health run.
|
|
#
|
|
# IT CANNOT CONTRADICT memory.physical_total. Both checks read one fact,
|
|
# node_health_mem_shortfall, computed once further up this file; this check does not measure
|
|
# memory at all. Its FAIL is gated on that fact being FAIL, so "memory was lost" has exactly
|
|
# one verdict on any host and both checks quote it.
|
|
#
|
|
# THE HONESTY TRAP, AND HOW IT IS AVOIDED. "No memattr line" means the node is unaffected
|
|
# ONLY if the kernel log was actually read AND still reaches back to early boot — every
|
|
# memattr diagnostic is printed in the first fraction of a second, and the ring buffer
|
|
# wraps. So this check SKIPs, with the reason, when dmesg could not be read at all, and
|
|
# SKIPs again when it was read but carries no boot anchor. Neither is allowed to become a
|
|
# PASS. memory.physical_total measures the SYMPTOM from /proc/zoneinfo and needs no kernel
|
|
# log at all, so a node whose log is unreadable is still not unmeasured.
|
|
- name: Assess — EFI Memory Attributes table (firmware bug + unvalidated kernel parse)
|
|
ansible.builtin.set_fact:
|
|
node_health_checks: "{{ node_health_checks + [{
|
|
'id': 'firmware.efi_memattr',
|
|
'title': 'EFI Memory Attributes table — corrupt table reserved as RAM by the kernel',
|
|
'status': memattr_status,
|
|
'detail': memattr_detail }] }}"
|
|
vars:
|
|
ansible_become: false
|
|
k: "{{ node_health_facts.klog }}"
|
|
z: "{{ node_health_facts.memory.zones }}"
|
|
# THE ONE MEMORY VERDICT, read (never re-derived) from the shared measurement computed
|
|
# near memory.physical_total. This check contributes the kernel-log facts only.
|
|
ms: "{{ node_health_mem_shortfall }}"
|
|
ma_state: "{{ k.memattr_state | default(none) }}"
|
|
# `Failed to map` means the bug FIRED — always at least a WARN, never a PASS. Whether it
|
|
# COST anything is not in the log: only ms.status can escalate this to FAIL, which is why
|
|
# this check and memory.physical_total can no longer disagree about lost memory.
|
|
memattr_status: >-
|
|
{{ 'SKIP' if not (k.available | bool)
|
|
else ('FAIL' if (ma_state == 'failed_to_map' and ms.status == 'FAIL')
|
|
else ('WARN' if ma_state in ['failed_to_map', 'bad_version']
|
|
else ('PASS' if ma_state == 'corrupt_rejected'
|
|
else ('PASS' if (k.boot_covered | bool) else 'SKIP')))) }}
|
|
# One remediation, quoted by both findings. NOTE what it must NOT say: there is no
|
|
# kernel cmdline workaround, because efi_memattr_init() runs before any efi= bail-out
|
|
# could take effect. Suggesting one would be a fix that quietly does nothing.
|
|
memattr_fix: >-
|
|
FIX: boot a kernel >= 6.13 (Debian 13: linux-image-amd64 from trixie-backports) —
|
|
upstream commit 8fbe4c49c0cc "efi/memattr: Ignore table if the size is clearly
|
|
bogus", first released in v6.13 and absent from v6.12 and from the current
|
|
linux-6.12.y stable branch. This node runs {{ node_health_facts.os.kernel | default('an unknown kernel') }}.
|
|
There is NO kernel cmdline workaround: efi_memattr_init() runs before any efi=
|
|
bail-out could take effect. Rebooting, clearing CMOS, changing a BIOS setting or
|
|
unplugging USB only change where the table lands and may APPEAR to fix it — they are
|
|
a lottery ticket, not a fix. Full write-up: infra/PROD-PROVISIONING.md §0b.
|
|
# The measurement, quoted from the shared fact — the ONLY thing this finding is allowed
|
|
# to say about memory being lost or intact. Figures come from /proc/zoneinfo, which the
|
|
# kernel log has no part in; the verdict word comes from ms.status, so it always agrees
|
|
# with memory.physical_total. When the measurement is missing it says so, and says why.
|
|
memattr_figures: >-
|
|
{{ ('MemTotal ' ~ ((z.managed_kb | int) / 1048576) | round(1) | string ~ ' GiB of '
|
|
~ ((z.present_kb | int) / 1048576) | round(1) | string ~ ' GiB present, i.e. '
|
|
~ ms.zones_pct | string ~ '% of the RAM this machine has was never handed to the
|
|
allocator (/proc/zoneinfo)')
|
|
if ms.zones_pct is number
|
|
else (('MemTotal is ' ~ ms.dimm_pct | string ~ '% short of the DIMM capacity SMBIOS
|
|
reports as installed (/proc/zoneinfo NOT read — '
|
|
~ (z.reason | default('no reason recorded', true)) ~ ')')
|
|
if ms.dimm_pct is number else '') }}
|
|
memattr_corroboration: >-
|
|
{{ (' MEASURED THIS BOOT, independently of this log (check memory.physical_total, verdict '
|
|
~ ms.status ~ '): ' ~ memattr_figures
|
|
~ (' — a catastrophic shortfall: memory IS lost on this boot.' if ms.status == 'FAIL'
|
|
else (' — an elevated shortfall, above the warn threshold.' if ms.status == 'WARN'
|
|
else ' — the normal few percent (kernel image, memmap, firmware
|
|
reservations, graphics stolen memory). NO measurable memory was lost
|
|
on this boot.')))
|
|
if (memattr_figures | trim | length) > 0
|
|
else (' Whether memory was lost on this boot could NOT be measured here: neither
|
|
present-vs-managed pages nor installed DIMM capacity was read — see check
|
|
memory.physical_total for the reasons.') }}
|
|
# The kernel log lines themselves, verbatim. A verdict the operator cannot check
|
|
# against the evidence is not much better than a wrong one.
|
|
memattr_evidence: >-
|
|
{{ ((' Kernel log: ' ~ (k.memattr_lines | join(' | ')))
|
|
if (k.memattr_lines | default([]) | length) > 0 else '')
|
|
~ ((' At boot the kernel reported '
|
|
~ ((k.memory_line.available_kb | int) / 1048576) | round(1) | string ~ ' GiB of '
|
|
~ ((k.memory_line.total_kb | int) / 1048576) | round(1) | string ~ ' GiB available, '
|
|
~ ((k.memory_line.reserved_kb | int) / 1048576) | round(1) | string ~ ' GiB reserved'
|
|
~ ' — the per-boot figure PROD-PROVISIONING.md §0b tabulates.')
|
|
if (k.memory_line is mapping and (k.memory_line.reserved_kb | default(none)) is number)
|
|
else '') }}
|
|
memattr_detail: >-
|
|
{%- if not (k.available | bool) -%}
|
|
the kernel log was NOT read — {{ k.reason | default('no reason recorded', true) }}.
|
|
Whether this node is affected is therefore UNKNOWN, not unaffected: the diagnostic
|
|
lives only in dmesg.{{ memattr_corroboration }}
|
|
{%- elif ma_state == 'failed_to_map' and ms.status == 'FAIL' -%}
|
|
THE BUG FIRED AND MEMORY IS LOST ON THIS BOOT — measured, not inferred from this log
|
|
line. The kernel failed to map the EFI Memory Attributes table at
|
|
{{ k.memattr_table_address | default('an unreported address') }}, which proves the
|
|
table was corrupt AND that this kernel trusted it far enough to memblock_reserve()
|
|
from its contents; the measurement below shows that reservation was the catastrophic
|
|
kind — a NEGATIVE tbl_size (num_entries x desc_size with bit 31 set), sign-extended
|
|
through phys_addr_t and clamped to PHYS_ADDR_MAX, reserving everything above the
|
|
table.{{ memattr_evidence }}{{ memattr_corroboration }} {{ memattr_fix }}
|
|
{%- elif ma_state == 'failed_to_map' -%}
|
|
THE BUG FIRED ON THIS BOOT AND THIS BOOT SURVIVED IT — not a pass, and not memory
|
|
loss either. The kernel failed to map the EFI Memory Attributes table at
|
|
{{ k.memattr_table_address | default('an unreported address') }}: the table was
|
|
corrupt and this kernel trusted it far enough to memblock_reserve() from its contents.
|
|
WHAT THAT COST is decided by the garbage VALUE at that address on this boot, not by
|
|
the address: catastrophic loss requires a NEGATIVE tbl_size (num_entries x desc_size
|
|
with bit 31 set) which sign-extends and clamps to PHYS_ADDR_MAX, whereas a garbage
|
|
tbl_size that stays POSITIVE reserves a modest, wrong amount that costs nothing
|
|
measurable and still fails the later memremap() that printed this line. This boot drew a survivable
|
|
value; the draw is repeated on EVERY boot, at the same address — this platform has
|
|
been seen to lose 13.3 GiB and to keep its full memory at one identical table address
|
|
(infra/PROD-PROVISIONING.md §0b).{{ memattr_evidence }}{{ memattr_corroboration }}
|
|
{{ memattr_fix }}
|
|
{%- elif ma_state == 'bad_version' -%}
|
|
EXPOSED, not immune, though this boot took the safe path. The firmware publishes a
|
|
CORRUPT EFI Memory Attributes table here too; this boot survived because its garbage
|
|
version field read {{ k.memattr_version | default('> 2') }}, which is > 2, so the
|
|
kernel bailed out BEFORE reserving anything from it. The outcome is re-decided on
|
|
EVERY boot: if that field reads <= 2 the kernel trusts the table and reserves whatever
|
|
tbl_size the garbage produces — nothing measurable if that value is positive,
|
|
everything above the table if it is negative.{{ memattr_evidence }}
|
|
{{ memattr_corroboration }} {{ memattr_fix }}
|
|
{%- elif ma_state == 'corrupt_rejected' -%}
|
|
the firmware publishes a corrupt EFI Memory Attributes table AND the running kernel
|
|
validated and rejected it (the >= 6.13 behaviour, commit 8fbe4c49c0cc). This bug
|
|
cannot cost this node memory on this or any future boot; no
|
|
action.{{ memattr_evidence }}{{ memattr_corroboration }}
|
|
{%- elif not (k.boot_covered | bool) -%}
|
|
NOT DETERMINED. The kernel log carries no memattr line, but it also no longer reaches
|
|
back to early boot (no "Linux version" / "BIOS-provided physical RAM map" anchor in
|
|
the ring buffer, which wraps). Every memattr diagnostic is printed within the first
|
|
fraction of a second, so its absence here proves NOTHING — this is an UNKNOWN, not a
|
|
pass. Read /var/log/kern.log for this boot, or re-run after a
|
|
reboot.{{ memattr_corroboration }}
|
|
{%- elif k.memattr_published is sameas true -%}
|
|
the firmware publishes an EFI Memory Attributes table at
|
|
{{ k.memattr_table_address | default('an unreported address') }} and the kernel
|
|
accepted it without complaint, in a log that still reaches back to early boot. Not
|
|
affected on this boot.
|
|
{%- elif k.memattr_published is sameas false -%}
|
|
this firmware publishes NO EFI Memory Attributes table (the UEFI config-table line
|
|
lists no MEMATTR=), so the bug cannot arise on this node. Normal for a Proxmox/OVMF
|
|
guest.
|
|
{%- else -%}
|
|
no UEFI config-table line in the kernel log at all — this node did not boot via UEFI,
|
|
so there is no EFI Memory Attributes table to be corrupt. Log reaches back to early
|
|
boot, so that absence is measured, not assumed.
|
|
{%- endif -%}
|