feat(shutdown): configure graceful node shutdown, and never scale a Delete-policy StatefulSet
All three nodes had to be powered off to move them onto a UPS, and there was
NO procedure: infra/cluster.sh stop is virsh-based and only ever applied to the
decommissioned dev cluster. The sequence was improvised live. Two defects came
out of doing it.

1. GRACEFUL NODE SHUTDOWN WAS UNCONFIGURED ON EVERY PROD NODE. No
   shutdownGracePeriod anywhere in infra/ansible/, so `shutdown -h` stopped k3s,
   containerd went with it, and every pod was SIGKILLed where it stood -- 9 CNPG
   instances mid-checkpoint, the UniFi VM, 25 attached Longhorn volumes.
   roles/k3s_server now sets kubelet-arg shutdown-grace-period=90s and
   shutdown-grace-period-critical-pods=20s.

   The half that silently defeats the other half: this is enforced by LOGIND,
   not the kubelet. The kubelet holds an inhibitor DELAY lock and systemd waits
   at most InhibitDelayMaxSec -- DEFAULT 5 SECONDS -- then proceeds regardless,
   truncating the drain with no error. The role ships a logind.conf.d drop-in
   (120) and ASSERTS cap >= grace period, because the failure is invisible.

2. SCALING A StatefulSet TO 0 DELETED ITS PVC AND VOLUME. monitoring/loki
   carries persistentVolumeClaimRetentionPolicy whenScaled: Delete, so the
   quiesce destroyed storage-loki-0 outright. Loki stores type: filesystem, so
   that PVC was the only copy; 72h retention bounded the loss, the mechanism
   does not. Symptom was the volume count going 25 -> 24, first misread as a
   miscount. Repaired: scale back to the declared 1 recreated the PVC and
   loki-0 is 2/2 Running.

New infra/maintenance/quiesce.sh (quiesce|resume|status) encodes the sequence
that worked and REFUSES to scale any whenScaled: Delete StatefulSet -- it stays
running, its volume hard-detaches, and it rebuilds on restart. A rebuild beats
a deletion. Discovery is computed from the live cluster, so a newly onboarded
service needs no edit here.

runbooks/cluster-maintenance-shutdown.md is the operator page: order in both
directions, TrueNAS-after-nodes (hard NFS mount wedges kubelet), the
un-hibernate-Postgres step Flux will NOT do for you, and a "looks broken but is
fine" section separating the 4/19 Flux cascade, the degraded-and-rebuilding
volume and the self-recovering keycloak-operator from the one thing that needs
a human (a stuck oauth2-proxy replica).

THE KUBELET CHANGE HAS NEVER BEEN APPLIED OR TESTED -- it needs a rolling k3s
restart, which is an operator action. Review config.yaml's kubelet-arg before
applying: a bad config.yaml is how k3s fails to come up. See the handoff entry.

Co-Authored-By: Claude Opus 5 (1M context) <[email protected]>
2026-10-17 22:26:47 -05:00

266 lines
14 KiB
Bash
Executable File

#!/usr/bin/env bash
# =================================================================================================
# quiesce.sh — bring the prod cluster to a safe standstill before powering nodes off, and bring it
# back afterwards. Companion to runbooks/cluster-maintenance-shutdown.md.
# =================================================================================================
# WHY THIS EXISTS. On 2026-10-17 all three nodes had to be powered off to move them onto a UPS, and
# there was NO procedure for it: `infra/cluster.sh stop` is `virsh`-based and only ever applied to
# the decommissioned dev cluster. The whole sequence was improvised live. This script is that
# sequence, so the next person does not improvise it.
#
# WHY IT IS NOT JUST `shutdown -h`. Graceful node shutdown was unconfigured on every prod node that
# day, so systemd stopped containerd and SIGKILLed every pod where it stood. roles/k3s_server now
# sets shutdown-grace-period (+ the logind InhibitDelayMaxSec cap that actually enforces it), which
# makes a bare reboot safe. This script is still the right tool for a PLANNED whole-cluster
# shutdown, for three reasons the kubelet's drain does not cover:
# 1. The UniFi VM needs an ACPI guest shutdown, not an eviction.
# 2. CloudNativePG wants hibernation, not pod deletion -- and hibernation is IMPERATIVE state
# that Flux will not set or clear for you.
# 3. Draining three nodes one at a time makes pods RESCHEDULE onto the survivors, churning
# Longhorn replicas for no reason when the whole cluster is going down anyway. Scaling in
# place avoids all of it.
#
# SAFE TO RE-RUN. Every step is idempotent and `resume` is the exact inverse of `quiesce`.
#
# WHAT IT DELIBERATELY DOES NOT DO: power anything off. Node poweroff is an operator action
# (CLAUDE.md §5) and needs the become password; the runbook gives the ansible one-liner. It also
# does not touch TrueNAS (not in the inventory, SSH refused -- web UI only) or the router.
set -euo pipefail
CONTEXT="${CONTEXT:-k3s-prod}"
KUBECTL=(kubectl --context "$CONTEXT" --request-timeout=30s)
TIMEOUT="${TIMEOUT:-600}"
# The three CloudNativePG clusters, as namespace/name. Hibernation is per-Cluster.
CNPG=(keycloak/keycloak-db nextcloud-db/nextcloud-db semaphore-db/semaphore-db)
log() { printf '\033[34m[quiesce]\033[0m %s\n' "$*"; }
ok() { printf '\033[32m[ ok ]\033[0m %s\n' "$*"; }
warn() { printf '\033[33m[warn]\033[0m %s\n' "$*"; }
die() { printf '\033[31m[fail]\033[0m %s\n' "$*" >&2; exit 1; }
need() { command -v "$1" >/dev/null || die "$1 not on PATH — run this inside ./infra/devcontainer/dev.sh"; }
# ---------------------------------------------------------------- discovery
# Every Deployment/StatefulSet whose pods mount a PVC — Longhorn OR the TrueNAS NFS bulk tier.
# Computed from the LIVE cluster rather than hardcoded, so a newly onboarded service is covered
# without anyone remembering to add it here. PROTECTED namespaces are excluded because scaling
# them down would remove the very machinery that performs the detach (longhorn-system), keep the
# API reachable (kube-system), or finish the hibernation and the VM shutdown (cnpg-system,
# kubevirt).
pvc_workloads() {
"${KUBECTL[@]}" get pods -A -o json | python3 -c '
import json,sys
PROTECT={"longhorn-system","kube-system","cilium-secrets","cnpg-system","kubevirt","flux-system","cdi"}
out={}
for p in json.load(sys.stdin)["items"]:
ns=p["metadata"]["namespace"]
if ns in PROTECT: continue
if not any(v.get("persistentVolumeClaim") for v in (p["spec"].get("volumes") or [])): continue
ow=(p["metadata"].get("ownerReferences") or [])
if not ow: continue
k,n=ow[0]["kind"],ow[0]["name"]
if k=="ReplicaSet": k,n="deployment",n.rsplit("-",1)[0]
elif k=="StatefulSet": k="statefulset"
else: continue # Jobs, and CNPG Clusters, are handled separately
out[(ns,k,n)]=1
for ns,k,n in sorted(out): print(ns,k,n)
'
}
# ---------------------------------------------------------------- the PVC-deletion guard
# *** DO NOT REMOVE THIS CHECK. IT EXISTS BECAUSE SCALING A StatefulSet DESTROYED DATA. ***
# A StatefulSet may carry `persistentVolumeClaimRetentionPolicy.whenScaled: Delete`, and then
# scaling it to 0 DELETES ITS PVCs -- and with them the Longhorn volumes. MEASURED 2026-10-17: the
# quiesce for the UPS move scaled `monitoring/loki` (whenScaled: Delete) to 0 and its
# `storage-loki-0` PVC and volume were deleted outright. Loki stores with `type: filesystem`, so
# that PVC was the only copy; 72h retention bounded the loss to a rolling window, but nothing about
# the mechanism is bounded -- the same action on a Delete-policy StatefulSet holding real state
# would be unrecoverable. The volume count going 25 -> 24 was the only visible symptom, and it was
# first misread as a miscount.
#
# So: such a StatefulSet is NEVER scaled. It is left RUNNING and its volume hard-detaches at
# poweroff, which costs a replica rebuild on restart (degraded -> healthy, automatic). A rebuild is
# an enormously better outcome than a deletion, and that is the whole trade being made here.
sts_deletes_pvc_on_scale() { # ns name -> 0 if scaling it would delete its PVCs
local policy
policy=$("${KUBECTL[@]}" -n "$1" get statefulset "$2" \
-o jsonpath='{.spec.persistentVolumeClaimRetentionPolicy.whenScaled}' 2>/dev/null || true)
[ "$policy" = "Delete" ]
}
wait_for() { # wait_for <description> <shell-condition>
local desc="$1" cond="$2" waited=0
log "waiting: $desc (up to ${TIMEOUT}s)"
until eval "$cond"; do
(( waited += 10 )); (( waited >= TIMEOUT )) && { warn "TIMED OUT waiting: $desc"; return 1; }
sleep 10
done
ok "$desc"
}
# ---------------------------------------------------------------- quiesce
do_quiesce() {
need kubectl; need python3
# Refuse to start if Longhorn is already unhealthy. Powering off on top of a degraded volume is
# how one replica becomes zero; better to stop here and let it rebuild first.
local unhealthy
unhealthy=$("${KUBECTL[@]}" -n longhorn-system get volumes.longhorn.io \
-o jsonpath='{range .items[*]}{.status.robustness}{"\n"}{end}' | grep -cvE '^(healthy|unknown)$' || true)
[ "$unhealthy" = "0" ] || die "$unhealthy Longhorn volume(s) are not healthy — fix or wait for rebuild BEFORE powering off"
ok "Longhorn: all volumes healthy"
# 1. Flux first, or it reverts every scale-down below within its reconcile interval.
log "suspending Flux Kustomizations"
local k
for k in $("${KUBECTL[@]}" -n flux-system get kustomizations -o name); do
"${KUBECTL[@]}" -n flux-system patch "${k}" --type=merge -p '{"spec":{"suspend":true}}' >/dev/null
done
ok "all Kustomizations suspended"
# 2. The VM needs an ACPI shutdown of the GUEST. KubeVirt does that on running:false; a plain
# pod eviction would be a power cut to the VM.
if "${KUBECTL[@]}" -n unifi get vm unifi >/dev/null 2>&1; then
log "ACPI-stopping the UniFi VM"
"${KUBECTL[@]}" -n unifi patch vm unifi --type=merge -p '{"spec":{"running":false}}' >/dev/null
fi
# 3. Postgres: hibernation is a clean smart shutdown that KEEPS the PVCs. CNPG does one instance
# at a time, primary last-ish, so this is not instant.
log "hibernating CloudNativePG clusters"
local c ns name
for c in "${CNPG[@]}"; do
ns="${c%%/*}"; name="${c##*/}"
"${KUBECTL[@]}" -n "$ns" annotate cluster.postgresql.cnpg.io "$name" \
cnpg.io/hibernation=on --overwrite >/dev/null 2>&1 || warn "could not hibernate $c"
done
# 4. Everything holding a PVC, scaled in place. NFS consumers first so nothing holds a hard
# TrueNAS mount; PiHole last because it is the LAN resolver.
log "scaling down PVC-holding workloads"
local line ns2 kind nm deferred=() skipped_delete_policy=()
while read -r ns2 kind nm; do
[ -z "${ns2:-}" ] && continue
if [ "$kind" = "statefulset" ] && sts_deletes_pvc_on_scale "$ns2" "$nm"; then
warn "SKIPPING $ns2/$nm — whenScaled: Delete would DELETE its PVC (see the guard above)."
warn " Left running; its volume hard-detaches at poweroff and rebuilds on restart."
skipped_delete_policy+=("$ns2/$nm")
continue
fi
if [ "$ns2" = "pihole" ]; then deferred+=("$ns2 $kind $nm"); continue; fi
"${KUBECTL[@]}" -n "$ns2" scale "$kind" "$nm" --replicas=0 >/dev/null 2>&1 \
&& printf ' scaled 0 %s/%s %s\n' "$ns2" "$kind" "$nm" \
|| warn "could not scale $ns2/$kind/$nm"
done < <(pvc_workloads)
for line in "${deferred[@]:-}"; do
[ -z "${line:-}" ] && continue
# shellcheck disable=SC2086
set -- $line
"${KUBECTL[@]}" -n "$1" scale "$2" "$3" --replicas=0 >/dev/null 2>&1 \
&& printf ' scaled 0 %s/%s %s (LAN DNS — expect name resolution to stop)\n' "$1" "$2" "$3"
done
# 5. The only assertion that matters. An attached volume at poweroff comes back degraded and
# rebuilds; this is what we are buying with all of the above.
wait_for "UniFi VMI gone" \
'[ "$('"${KUBECTL[*]}"' -n unifi get vmi --no-headers 2>/dev/null | wc -l)" = "0" ]' || true
wait_for "all Postgres instances stopped" \
'[ "$('"${KUBECTL[*]}"' get pods -A --no-headers 2>/dev/null | grep -cE "(keycloak|nextcloud|semaphore)-db-[0-9]")" = "0" ]' || true
wait_for "all Longhorn volumes detached" \
'[ "$('"${KUBECTL[*]}"' -n longhorn-system get volumes.longhorn.io -o jsonpath="{range .items[*]}{.status.state}{\"\n\"}{end}" 2>/dev/null | grep -c attached)" = "0" ]' || \
warn "some volumes are STILL ATTACHED — they will come back degraded and rebuild; acceptable, but note which"
if [ "${#skipped_delete_policy[@]}" -gt 0 ]; then
echo
warn "NOT scaled down (whenScaled: Delete — scaling them would delete their PVCs):"
printf ' %s\n' "${skipped_delete_policy[@]}"
warn "Expect these volumes to come back 'degraded' and rebuild. That is correct and automatic."
fi
echo
ok "QUIESCED. Safe to power off."
cat <<'NEXT'
Next, from inside the devcontainer (it holds the become password):
cd /work/infra/ansible && ansible -i inventory/hosts.ini k3s_prod -b \
-m shell -a 'shutdown -h +1 "maintenance"'
THEN, in this order and not before:
1. TrueNAS (192.168.2.30) — web UI only; not in the ansible inventory and SSH is refused.
2. Router / switch last.
NEXT
}
# ---------------------------------------------------------------- resume
do_resume() {
need kubectl
# THE STEP THAT IS ALWAYS FORGOTTEN. Hibernation is imperative state: Flux neither sets nor
# clears it, so resuming Flux alone leaves all three databases down and every app that needs
# one looking broken for reasons that point nowhere near Postgres.
log "un-hibernating CloudNativePG clusters"
local c ns name
for c in "${CNPG[@]}"; do
ns="${c%%/*}"; name="${c##*/}"
"${KUBECTL[@]}" -n "$ns" annotate cluster.postgresql.cnpg.io "$name" \
cnpg.io/hibernation=off --overwrite >/dev/null 2>&1 || warn "could not un-hibernate $c"
done
# Flux restores every replica count AND the VM's running:true from git, so nothing here needs to
# undo the scale-downs by hand.
log "resuming Flux Kustomizations"
local k
for k in $("${KUBECTL[@]}" -n flux-system get kustomizations -o name); do
"${KUBECTL[@]}" -n flux-system patch "${k}" --type=merge -p '{"spec":{"suspend":false}}' >/dev/null
done
ok "all Kustomizations resumed"
wait_for "Flux fully reconciled" \
'[ "$('"${KUBECTL[*]}"' -n flux-system get kustomizations --no-headers 2>/dev/null | grep -vc True)" = "0" ]' || \
warn "some Kustomizations are not Ready — the graph serialises behind platform-config, so give it a few minutes before worrying"
echo
ok "RESUMED."
cat <<'NEXT'
Known cold-start race, not a fault in this script: oauth2-proxy performs OIDC discovery at
startup and exits 1 on the 503 it gets while Keycloak is still coming up, then sits in
exponential CrashLoopBackOff. If a replica is stuck, delete the pod once:
kubectl --context k3s-prod -n oauth2-proxy delete pod <name>
NEXT
}
do_status() {
need kubectl
printf 'nodes: %s Ready\n' "$("${KUBECTL[@]}" get nodes --no-headers | grep -c ' Ready')"
printf 'flux: %s/%s Ready\n' \
"$("${KUBECTL[@]}" -n flux-system get kustomizations --no-headers | grep -c True)" \
"$("${KUBECTL[@]}" -n flux-system get kustomizations --no-headers | wc -l)"
printf 'longhorn: %s attached, %s detached, %s not healthy\n' \
"$("${KUBECTL[@]}" -n longhorn-system get volumes.longhorn.io -o jsonpath='{range .items[*]}{.status.state}{"\n"}{end}' | grep -c attached)" \
"$("${KUBECTL[@]}" -n longhorn-system get volumes.longhorn.io -o jsonpath='{range .items[*]}{.status.state}{"\n"}{end}' | grep -c detached)" \
"$("${KUBECTL[@]}" -n longhorn-system get volumes.longhorn.io -o jsonpath='{range .items[*]}{.status.robustness}{"\n"}{end}' | grep -cvE '^(healthy|unknown)$' || true)"
printf 'postgres: %s instance pod(s)\n' \
"$("${KUBECTL[@]}" get pods -A --no-headers | grep -cE '(keycloak|nextcloud|semaphore)-db-[0-9]' || true)"
printf 'unifi VM: %s VMI\n' "$("${KUBECTL[@]}" -n unifi get vmi --no-headers 2>/dev/null | wc -l)"
}
case "${1:-}" in
quiesce) do_quiesce ;;
resume) do_resume ;;
status) do_status ;;
*) cat >&2 <<USAGE
usage: $0 {quiesce|resume|status}
quiesce suspend Flux, ACPI-stop the UniFi VM, hibernate Postgres, scale down every
PVC-holding workload, and wait for all Longhorn volumes to detach.
Does NOT power anything off — see runbooks/cluster-maintenance-shutdown.md.
resume the exact inverse: un-hibernate Postgres, resume Flux, wait for reconcile.
status one-screen readout of nodes / Flux / Longhorn / Postgres / VM.
Run it inside the pinned toolbox, which supplies kubectl and the context:
./infra/devcontainer/dev.sh run bash -c './infra/maintenance/quiesce.sh status'
USAGE
exit 2 ;;
esac