feat(prod): enable node 2 + HARDWARE FAULT — it addresses 2.6 GiB of its 16 GB

k3s-prod-2 (192.168.2.11) came online 2026-09-01. Enabled in the inventory, baseline package
floor installed, first health run completed. Vaulted become works on it unchanged.

*** OPEN FAULT: the node can only address ~2.6 GiB of a healthy, correctly-installed 16 GB
DIMM. *** Recorded in PROD-PROVISIONING §0b.

  dmidecode        16 GB Samsung M471A2K43DB1-CTD in DIMM1 @ 2667 MT/s (DIMM3 empty)
  BIOS e820        reports ~16 GiB usable, incl. 0x100000000-0x42f7fffff
  kernel           Memory: 2568544K/16546088K available (13958980K RESERVED)
  last_pfn         revised DOWN 0x42f800 (~16.7 GiB) -> 0xc3c10 (~3.06 GiB) in early boot
  zones            Normal present 3340288 pages (~12.7 GiB) but MANAGED 0
  MemTotal         2,753,284 kB = 2.6 GiB

The DIMM is NOT the problem: it is present, correctly identified, and at rated speed. The
kernel sees all 16 GB and then reserves 13.3 GiB. Everything below ~3 GiB usable, everything
above 4 GiB present-but-unmanaged — the signature of memory remapping above 4 GB not being
applied, not of failing memory. Node 1 is the control: identical chassis, identical BIOS R21
Ver. 02.26.00, identical CPU, and it addresses its full 31 GiB. Per-machine state, not a
firmware-version defect.

WARNING RECORDED: do NOT assume the incoming 32 GB fixes this. If the fault is the slot, the
board or a BIOS setting rather than the DIMM, 32 GB presents identically and the money is
wasted. Verify MemTotal after any RAM change.

ALSO FOUND — the prod nodes are NOT hardware-symmetric:
  node 1  Micron C400 512GB SATA SSD (~2011) — 69% life, 15 grown bad blocks, 187 erase
          failures, 32 unexpected power losses
  node 2  Samsung PM9A1 512GB NVMe        — 96% life, 2142 power-on hours, 34 unexpected
          power losses, overall-health PASSED
Same chassis, same BIOS, same CPU, same partition layout — very different storage. §2 requires
an identical disk layout across all three nodes because Longhorn replica placement assumes
symmetry, so this asymmetry is now a live input to the disk decision rather than a footnote.
Node 2's NVMe is the drive node 1 should have had.

Node 2 otherwise: 0 FAIL / 3 WARN / 12 PASS / 2 SKIP. Same three WARNs as node 1 (swap still
active pending full baseline, single IPv4 resolver, and the NVMe's 34 unexpected power losses),
plus the same unknowable-ECC SKIP.

Serves: R-ENV-01, R-ENV-03, R-OBS-04. Task: T-7.1.

Co-Authored-By: Claude Opus 5 (1M context) <[email protected]>
This commit is contained in:
jakman85andClaude Opus 5 committed 2026-09-01 20:56:58 -05:00
1 parent f1daa8cae0
commit cb69a53825
2 files changed
+44 -5

No files matched your search

+37
View File
@@ -37,6 +37,43 @@ Dev nodes for comparison: 8 vCPU / 24 GiB / Debian 13, **two** dedicated data di
---
## 0b. OPEN HARDWARE FAULT — `k3s-prod-2` can only address ~2.6 GiB of its 16 GB
Found 2026-09-01 by `playbooks/node-health.yml` on node 2's first health run. **Do not install
more RAM until this is understood** — see the warning at the end.
| Evidence | Reading |
|---|---|
| DMI (`dmidecode -t memory`) | **16 GB Samsung M471A2K43DB1-CTD in DIMM1 @ 2667 MT/s**, DIMM3 empty |
| BIOS e820 map | reports ~16 GiB usable, incl. `0x100000000-0x42f7fffff` |
| Kernel summary | `Memory: 2568544K/16546088K available (13958980K reserved)` |
| `last_pfn` | revised **down** from `0x42f800` (~16.7 GiB) to `0xc3c10` (~3.06 GiB) in early boot |
| Zones | `Normal` zone `present 3340288` pages (~12.7 GiB) but **`managed 0`** |
| `MemTotal` | **2,753,284 kB ≈ 2.6 GiB** |
| Memory blocks | 127 online, 128 MiB block size |
**The DIMM is healthy.** It is present, correctly identified, and running at its rated speed. The
kernel *sees* all 16 GB and then reserves 13.3 GiB of it. Everything below ~3 GiB is usable and
everything above 4 GiB is present-but-unmanaged — the classic signature of **memory remapping
above 4 GB not being applied**, not of failing memory.
Node 1 is the control: **identical** HP EliteDesk 800 G5 Mini, **identical** BIOS R21 Ver. 02.26.00,
identical i7-9700T — and it addresses its full 31 GiB. So this is not a firmware-version defect; it
is per-machine state.
To investigate, cheapest first:
- [ ] Compare node 2's BIOS settings against node 1 directly. Look for a memory remap / "Above 4G
decoding" style option, and for any memory-limit or 32-bit-addressing setting.
- [ ] Clear CMOS / load setup defaults on node 2, then re-check `MemTotal`.
- [ ] Reseat the DIMM; try it in DIMM3; try it in node 1 (swap test) — that isolates DIMM vs slot
vs board in one move.
- [ ] `memtest86+` if the above do not resolve it.
> ⚠ **Do not assume the incoming 32 GB fixes this.** If the fault is the slot, the board, or a BIOS
> setting rather than the DIMM, 32 GB will present exactly the same way and the money is wasted.
> **Verify `MemTotal` after any RAM change** — `playbooks/node-health.yml -e node_health_hosts=k3s_prod`
> reports it. A node that can address 2.6 GiB cannot run k3s + Longhorn + a workload share.
## 1. Firmware / BIOS (per node, before OS install)
- [ ] **Virtualization enabled** — VT-x *and* VT-d. Required for KubeVirt (R-PLAT-03); verify after
+7 -5
View File
@@ -87,11 +87,13 @@ proxmox ansible_host=192.168.2.102 ansible_port=22 ansible_user=root ansible_ssh
k3s-prod-1 ansible_host=192.168.2.10 ansible_port=22 k3s_node_ip=192.168.2.10
[k3s_prod_secondary]
# Addresses for nodes 2/3 ARE decided (operator, 2026-08-31 — infra/PROD-PROVISIONING.md
# §0), but the nodes themselves are NOT yet racked/imaged/reachable. Left commented so
# no play can accidentally target a host that isn't there; uncomment each line only once
# that node is actually on the bench and answering SSH.
# k3s-prod-2 ansible_host=192.168.2.11 ansible_port=22 k3s_node_ip=192.168.2.11
# Uncomment a node only once it is actually on the bench and answering SSH, so no play can
# target a host that isn't there. k3s-prod-2 came online 2026-09-01 (imaged identically to
# node 1: same HP EliteDesk 800 G5 Mini, same BIOS R21 02.26.00, same i7-9700T, same
# partition layout) but with a SAMSUNG PM9A1 NVMe instead of node 1's 2011 SATA C400 — the
# nodes are NOT hardware-symmetric, which matters for the §2 Longhorn/etcd disk decision.
# node 3 remains commented until it is racked.
k3s-prod-2 ansible_host=192.168.2.11 ansible_port=22 k3s_node_ip=192.168.2.11
# k3s-prod-3 ansible_host=192.168.2.12 ansible_port=22 k3s_node_ip=192.168.2.12
# Umbrella group group_vars/k3s_prod/ attaches to (mirrors dev's [k3s_servers:children]